Installation Guide

8 31-2000374 Rev. 1
Installation Instructions
6
THREE-CONDUCTOR BRANCH CIRCUIT CONNECTION
NOTE:Ifresidenceleadsarealuminumconductors,see
WARNINGinSection4,ElectricalRequirements.
Whenconnectingtoathree-conductorbranchcircuit,if
localcodespermit:
A. Connecttheovengroundconductoralongwiththe
neutral(white)leadtothebranchcircuitneutral
(whiteorgrayincolor),usingawirenut.
B.Connecttheovenredleadtothebranchcircuitred
leadandtheovenblackleadtothebranchcircuit
blackleadinaccordancewithlocalcodes,using
wirenuts.
C.Installproperstrainreliefclamp.
D.Installjunctionboxcover.
7
FOUR-CONDUCTOR BRANCH CIRCUIT CONNECTION
NOTE:Ifresidenceleadsarealuminumconductors,seeWARNINGinSection4,ElectricalRequirements.
NOTE: IfusingaGFIbreaker,thegroundwiremustbeinstalledcorrectlytopreventbreakerfromtripping.Referto
latesteditionoftheNEC,NFPANo.70,availablefromtheNationalFireProtectionAssociation.
Whenconnectingtoafour-conductorbranchcircuit,iflocalcodespermit:
A.Freetheneutral(white)leadfrombeingrestrainedto
anyotherwires.Ifnecessary,cuttheneutral(white)
leadandthenre-stripittoexposetheproperlength
ofconductor.
B.Attachtheappliancegroundinglead(greenorbare
copper)inaccordancewithlocalcodes.
C.Connecttheovenneutral(white)leadtothebranch
circuitneutral(whiteorgray)inaccordancewithlocal
codes,usingawirenut.
D.Connecttheovenredleadtothebranchcircuitred
leadandtheovenblackleadtothebranchcircuitblack
leadinaccordancewithlocalcodes,usingwirenuts.
E.Installproperstrainreliefclamp.
F.Installjunctionbox
cover.
8
SLIDING THE OVEN INTO THE OPENING
A.Loop(do not tie)a36”(92cm)stringaroundthe
conduitbeforetheovenisslidintoplace.Thiswill
keeptheconduitfromfallingbehindtheoven.
B.Liftovenintocabinetcutoutusingtheovenopening
asagrip.Donotliftthedoorbythehandle!Carefully
pushagainstovenfrontframe.Donotpushagainst
outsideedges.
C.Asyouslidetheovenback,pullthestringsothatthe
conduitwilllieinanaturalloop,behindtheoven.
D.Whenyouaresuretheconduitisoutoftheway,
slidetheoven3/4waybackintotheopening.
Removethestringbypullingononeendoftheloop.
Groundand
neutralwires(white)
TapeorCrimp
Neutralwire
connection
Black
Red
Branch
circuit
Alternate
knockout
Range
conduit
snaps
intobox
JunctionBoxCover
JunctionBoxCover
White
Black
Red
Branch
circuit
Ground
wires
Alternate
knockout
Range
conduit
snaps
intobox
Pulloutonstring
loopwhilepush-
ingtheoveninto
thecabinet