Installation Guide

31-2000374 Rev. 1 7
Installation Instructions
4
ELECTRICAL REQUIREMENTS (CONT)
Thisappliancemustbesuppliedwiththepropervoltage
andfrequencyandconnectedtoanindividual,properly
groundedbranchcircuit,protectedbyacircuitbreaker
orfuse.Seetheratingplatelocatedontheovenframe
todeterminetheratingoftheproduct.
Usethechartbelowtodeterminetheminimum
recommendeddedicatedcircuitprotection:
DONOTshortentheflexibleconduit.Theconduitstrain
reliefclampmustbesecurelyattachedtothejunction
boxandtheflexibleconduitmustbesecurelyattached
totheclamp.Iftheflexibleconduitwillnotfitwithinthe
clamp,donotinstalltheovenuntilaclampoftheproper
sizeisobtained.
The3powerleadssuppliedwiththisapplianceare
suitableforconnectiontoheaviergaugehousehold
wiring.Theinsulationofthese3leadsisratedfor
temperaturesmuchhigherthanthetemperaturerating
ofthehouseholdwiring.Thecurrent-carryingcapacity
oftheconductorisgovernedbythewiregaugeandthe
temperatureratingoftheinsulationaroundthewire.
5
MAKE ELECTRICAL CONNECTIONS
WARNING
Switchpoweroffattheservice
panelandlocktheservicedisconnectingmeansto
preventpowerfrombeingswitchedonaccidentally.
Whentheservicedisconnectingmeanscannotbe
locked,securelyfastenaprominentwarningdevice,
suchasatag,totheservicepanel.
Placeovenontableorplatformevenwiththecutout
opening.Connecttheflexibleconduittotheelectrical
junctionboxasshown*.Positiontheconduitinsucha
mannerthatitwillliebehindtheunitinanaturalloop
whentheovenisinstalled.Youwillneedtopurchase
anappropriatestrainreliefclamptocompletethe
connectionoftheconduittothejunctionbox.
KW Rating
240V
KW Rating
208V
Recommended
Circuit Size
(Dedicated)
≤4.8KW ≤4.1KW 20Amp
4.9KW–7.2KW 4.2KW–6.2KW 30Amp
7.3KW–9.6KW 6.3KW–8.3KW 40Amp
9.7KW–12.0KW 8.4KW–10.4KW 50Amp
RatingPlateLocation
NOTE:Ratingplateislocatedonovensidetrim,side
frontframeorlowerfrontframe.
JunctionBoxLocation
StrainReliefClamp(not
included)mustbeused
atJunctionBox.
Conduit
Placeovenona
supporttoassistin
connectingconduit,
mustsupport
220lbs(99.8kg).
Ground
Red
White
Black
*Ovenscomeequippedwitha40”longconduit.Ifalongerconduitisdesired,theremaybeoneavailableforyourmodel.Tocheckavailabilityororder
parts,call800.561.3344.