Installation Guide
3 A
CUTOUT FOR SINGLE OVENS IN WALL CABINET
NOTE: If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick,
shim both sides equally to establish the cutout width.
3 B
CUTOUT FOR INSTALLATION OVER A
WARMING DRAWER
NOTE: Install the oven only with specific models listed on the label located on top of the oven.
NOTE: Additional clearances between cutouts may be required. Check to be sure the oven
supports above the Warming Drawer location do not obstruct the required interior depth and height.
When installing a Warming Drawer below a double oven, a separate 120V, 60 HZ, properly
grounded receptacle must be installed. Refer to installation instructions packed with the Warming
Drawer for specific installation requirements.
Anti-Tip Block Against
Rear Wall Per Warming
Drawer Requirement
2" (5.1 cm)
Min.
Per Warming
Drawer
Requirement
Cutout –
observe all
dimensions and
requirements.
Cutout –
observe all
dimensions and
requirements.
30” (76.2 cm) Min. if both ovens are French Door
14” (35.6 cm) Min. if only one oven is French Door
Center Line Center Line
30” Models
58
1
»2” (148.6 cm) if both ovens are French Door
42
1
»2” (108 cm) if only one oven is French Door
These ovens are not approved
for stackable installations.
Side-by-Side Installations
Install two ovens in separate cutouts.
C
K
EE
L
Dimension Dimension Description 30” Single Oven
A Cabinet width 30” (76.2 cm)
B Cutout width 28
1
»2” (72.4 cm) min.
28
5
»8” (72.7 cm) max.
C Cutout height 27
1
»4” (69.2 cm) min.
27
5
»16” (69.4 cm) max.
D Clearance from cutout - side edges*
11
»16” (1.75 cm)
E Door swing depth - Allow additional clearances for
installation and oven usage
16
1
»4” (41.3 cm) min.
F Clearance from cutout - top* 1” (2.5 cm) min
(1
1
»4” (3.2 cm)
G Clearance from cutout - bottom* 1
1
»4” (3.2 cm)
H Junction box location 9
1
»2” (24.1 cm) max.
right side only
J Door swing width - Allow additional clearances for
installation and oven usage
14” (35.6 cm) min.
K Countertop or cabinet door protrusion (measure if exist) Measure “K”
L Gap between edge of countertop or cabinet door
to cabinet opening
If K = 0, L = 0, Otherwise
L = K + 1” (2.54 cm) min.
P Junction Box location 5-1/4” (13.34 cm) max.
R Junction Box location 2-1/2” (6.35 cm) max.
B
A
Recommended
Cutout Location from
Floor
32
1
»2” (82.6 cm)
16
1
»4” (41.3 cm) Min.
D
F
G
C
* Refers to minimum clearance required for wall oven installation and does not reflect actual product dimensions.
H
P
R
E
J
J
Junction Box
Location (junction
box may be
located in
adjacent cabinet)
Cutout Depth
23
1
»2”
(59.7 cm) Min.
Opening
Between
Inside Walls
Must be at
Least 28
1
»2”
(72.4 cm)
Wide
NOTE: Allow
1/4” (0.64 cm)
clearances from
side edges of
oven door.