Installation Instructions
Installation Preparation
4
ELECTRICAL REQUIREMENTS
Single Advantium/Convection 120 
Installation:
This product requires a 120-volt, 60 Hz, 15-amp 
circuit and draws 1.8 kilowatts. This product must 
be connected to a supply circuit of the proper 
voltage and frequency. 
• Wire size must conform to the requirements of 
the National Electrical Code or the prevailing local 
code for this kilowatt rating.
• The power supply cord and plug should be 
brought to a separate 15 or 20 ampere branch 
circuit single grounded receptacle. The outlet box 
should be located within reach of the 48” power 
cord.
ELECTRICAL LOCATION
GROUNDING 
INSTRUCTIONS
This appliance must be grounded.  In the event of 
an electrical short circuit, grounding reduces the 
risk of electric shock by providing an escape wire 
for electric current.  This appliance is equipped 
with a cord having a grounding wire with a 
grounding plug.  The plug must be plugged into 
an outlet that is properly installed and grounded.
WARNING
 Improper use of the 
grounding plug can result in a risk of 
electric shock.
IMPORTANT: (Please read carefully).
The power cord of this appliance is equipped with 
a three-prong (grounding) plug that mates with a 
standard three-prong grounding wall receptacle 
to minimize the possibility of electric shock. 
Consult a qualified electrician or serviceman if 
the grounding instructions are not completely 
understood, or if doubt exists as to whether the 
appliance is properly grounded.
• Where a standard two-prong wall receptacle is 
encountered, it is the personal responsibility and 
obligation of the consumer to have it replaced with  
a properly grounded three-prong wall receptacle. 
Do not, under any circumstances, cut or remove 
the third (ground) prong from the power cord.
DO NOT USE AN EXTENSION CORD.  If the 
power supply cord is too short, have a qualified 
electrician or serviceman install an outlet near the 
appliance.
Install a recessed electrical outlet in the back 
wall of the opening within 6Ǝ of either side and 
at least 9Ǝ above the cutout floor.
Locate outlet box in the shaded area
6”