Installation Guide

10 31-2000814 Rev. 1
Installation
4
CONVERTING TO PROPANE (LP)
GAS OR CONVERTING BACK
TO NATURAL GAS FROM
PROPANE (LP)
7KLVUDQJHOHDYHVWKHIDFWRU\VHWIRUXVHZLWKQDWXUDO
JDV,I\RXZDQWWRFRQYHUWWRSURSDQH/3JDVWKH
conversion must be performed by a qualified propane
(LP) gas installer.
The conversion orifices
and instructions can
be found on back of
the range.
Keep these
instructions and all
orifices in case you
ZDQWWRFRQYHUWEDFN
to natural gas.
5
GAS SUPPLY
WARNING
)LUH+D]DUG'RQRWXVHDIODPHWR
check for gas leaks.
WARNING
([SORVLRQ+D]DUG'RQRWH[FHHG
IWOEVRIWRUTXHZKHQPDNLQJJDVOLQHFRQQHFWLRQV
Overtightening may damage the pressure regulator
UHVXOWLQJLQILUHRUH[SORVLRQKD]DUG
Gas Pressure Regulator
You must use the gas pressure regulator supplied
ZLWKWKLVUDQJH)RUSURSHURSHUDWLRQVWKHLQOHW
SUHVVXUHWRWKHUHJXODWRUVKRXOGEHDVIROORZV
Natural Gas:
0LQLPXPSUHVVXUH´RI:DWHU&ROXPQ
0D[LPXPSUHVVXUH´RI:DWHU&ROXPQ
Propane (LP) Gas:
0LQLPXPSUHVVXUH´RI:DWHU&ROXPQ
0D[LPXPSUHVVXUH´RI:DWHU&ROXPQ
If you are not sure about the inlet pressure contact
local gas supplier.
NOTE:$JDVVKXWRIIYDOYHLVVKLSSHGZLWKWKLVUDQJH
and should be installed at the rear of the range near
WKHIORRUZLWKWKHKDQGOH
IDFLQJGRZQZDUG7KLVVKXW
off valve is to be used in the
event that service is required.
7RDFFHVVWKHVKXWRIIYDOYH
remove the toe-kick panel
and reach under the range.
$QRSWLRQDO´HOERZLV
provided for connection to
the range gas inlet.
5
GAS SUPPLY (cont.)
Shut off the main gas supply valve before
disconnecting the old range and leave it off until
the new hook-up has been completed. Don’t
forget to relight the pilot on other gas appliances
when you turn the gas back on.
%HFDXVHKDUGSLSLQJUHVWULFWVPRYHPHQWRIWKHUDQJH
WKHXVHRID&6$,QWHUQDWLRQDOFHUWLILHGIOH[LEOHPHWDO
appliance connector is recommended unless local
codes require a hard-piped connection.
,IWKHKDUGSLSLQJPHWKRGLVXVHG\RXPXVWFDUHIXOO\
DOLJQWKHSLSHWKHUDQJHFDQQRWEHPRYHGDIWHUWKH
connection is made.
7RSUHYHQWJDVOHDNVSXWSLSHWKUHDGVHDODQWRQRU
ZUDSSLSHWKUHDGWDSHZLWK7HIORQDURXQGDOOPDOH
H[WHUQDOSLSHWKUHDGV
A. Install a manual shut-off valve in the gas line in an
easily accessed location outside of the range. Make
VXUHHYHU\RQHRSHUDWLQJWKHUDQJHNQRZVZKHUH
DQGKRZWRVKXWRIIWKHJDVVXSSO\WRWKHUDQJH
% ,QVWDOOPDOH´IODUHXQLRQDGDSWHUWRWKH´
NPT internal thread at inlet of the shut-off valve on
WKHUDQJH8VHDEDFNXSZUHQFKRQWKHVKXWRII
valve to avoid damage.
& ,QVWDOOPDOH´RU´IODUHXQLRQDGDSWHUWRWKH
137LQWHUQDOWKUHDGRIWKHKRXVHVKXWRIIYDOYH
taking care to back-up the shut-off valve to keep it
from turning.
' &RQQHFWIOH[LEOHPHWDODSSOLDQFHFRQQHFWRUWRWKH
adapter on the range. Position range to permit
connection at the house shut-off valve.
( :KHQDOOFRQQHFWLRQVKDYHEHHQPDGHPDNHVXUH
all range controls are in the off position and turn
on the main gas supply valve. Use a liquid leak
detector at all gas connections to check for leaks
in the system.
:KHQXVLQJSUHVVXUHVJUHDWHUWKDQSVLJWR
SUHVVXUHWHVWWKHJDVVXSSO\V\VWHPRIWKHUHVLGHQFH
disconnect the range and individual shut-off valve
from the gas supply piping. When using pressures
RISVLJRUOHVVWRSUHVVXUHWHVWWKHJDVVXSSO\
V\VWHPVLPSO\LVRODWHWKHUDQJHIURPWKHJDVVXSSO\
system by closing the individual shut-off valve.
:KHQFKHFNLQJIRUSURSHURSHUDWLRQRIWKHUHJXODWRU
the inlet pressure must be at least 1” greater than the
operating (manifold) pressure as given on rating label
of product.
7HIORQ5HJLVWHUHGWUDGHPDUNRI'X3RQW
Gas Inlet
Oven
Regulator
Cooktop Regulator
Propane
Conversion Kit