Quick Spec
CGU486SDLSS
GE Café
™
Series 48" Professional Gas Rangetop with
6 Burners and Griddle (Natural Gas)
DIMENSIONS AND INSTALLATION INFORMATION
For answers to your Monogram, GE Café
™
Series, GE Profile
™
Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center
®
Service, 800.626.2000.
Specification Revised 6/17
BACKSPLASH ACCESSORIES: The rangetop requires a 12" minimum
clearance to a vertical combustible surface at the rear. A backsplash
is required for installations with less than 12" clearance. The following
backsplash accessories are available, or a custom, non-combustible
backsplash can be used.
UXADJB48PSS, 48" backsplash with shelf
BACKSPLASH WITH WARMING SHELF: All Professional Hoods
feature infrared warming lights. The 30"-36" adjustable backsplash with
warming shelf is a perfect complement when installed with the tapered or
straight-sided hoods.
- Restaurant-Style Professional Hoods are shipped with a 22" stainless
steel backsplash and warming shelf.
ADVANCE PLANNING FOR PROFESSIONAL RANGETOPS:
Professional rangetops offer a number of choices in size and rangetop
configurations.
- All Professional rangetops are factory set for natural or liquid propane
gas. The correct model should be ordered for the installation situation.
NOTE: Conversion kits are included with the rangetop if the wrong gas
type was ordered. High Altitude kit, WB28K10553, is also available. The
kits must be installed by a qualified service technician at additional cost.
ELECTRICAL REQUIREMENTS: Rangetops must be supplied with
120V, 60Hz, and connected to an individual, properly grounded branch
circuit protected by a 15 amp circuit breaker or time-delay fuse.
GAS SUPPLY:
- Natural gas models are designed to operate at 5" water column
pressure. For proper operation, the pressure of the natural gas supplied
to the regulator must be between 7" and 13" water column.
- The liquid propane models are designed to operate at 10" water
column pressure. For proper operation, the pressure of the LP source
to the regulator must be between 11" and 13" water column.
Universal Utility Locations
Side View with a Backsplash