Spec Sheet
Café
™
48" Commercial-Style Gas Rangetop
with 6 Burners and Griddle
CGU486P4TW2 / CGU486P2TS1 / CGU486P3TD1 (NATURAL GAS)
For answers to your Café™ product questions, visit our website at cafeappliances.com.
DIMENSIONS AND INSTALLATION
Commercial-Style rangetops oer a number of choices in size and rangetop configurations.
Backsplash Accessories: The rangetop requires a 12" minimum clearance to a vertical
combustible surface at the rear. A backsplash is required for installations with less than
12" clearance. The following backsplash accessories are available, or a custom, non-
combustible backsplash can be used.
UX12BS48PSS, 12" backsplash
Backsplash with Warming Shelf: All Professional Hoods feature infrared warming lights.
The 30"-36"H adjustable backsplash with warming shelf is a perfect complement when
installed with the tapered or straight-sided hoods.
UXADBS48PSS, 30-36" backsplash with shelf
Advance Planning for Commercial-Style Rangetops: Commercial-Style rangetops oer a
number of choices in size and rangetop configurations.
All Commercial-Style rangetops are factory set for natural gas.
Note: Conversion kits are included with the rangetop if the wrong gas type was ordered.
High Altitude Natural Gas, WB28X39728 and High Altitude LP, WB28X39729, are also
available. The kits must be installed by a qualified service technician at additional cost.
Electrical Requirements: Rangetops must be supplied with 120V, 60Hz, and connected
to an individual, properly grounded branch circuit protected by a 15 amp circuit breaker
or time-delay fuse.
Gas Pressure Regulator:
You must use the gas pressure regulator supplied with this rangetop. For proper operations
the inlet pressure to the regulator should be as follows:
Natural Gas:
Minimum pressure: 6" of Water Column / Maximum pressure: 13" of Water Column
Propane (LP) Gas:
Minimum pressure: 11" of Water Column / Maximum pressure: 13" of Water Column
See installation instructions for more details
Product Dimensions and Clearance:
A suitable overhead vent hood is required for models with a grill and is recommended
for all other models. Due to the high heat capacity of this unit, particular attention should be
paid to the hood and ductwork installation to assure it meets local building codes.
Clearances between rangetop and side wall or combustible material must
be at least 12" on each side.
Allow 8" free space below the top surface of countertop. Allow additional clearances below
the burner box to install the regulator and make house gas supply connections. Use a 90°
elbow to route the gas connections and limit interference with drawers or
other cabinetry.
* The opening between a 4" high backsplash must be 36" to allow the rangetop to slide
back against the wall.
WARNING: Installations without a hood require 48" minimum to combustibles above
the rangetop. A custom hood installation with exposed horizontal combustible surfaces
must have an “auto-on” feature. Refer to hood installation instructions for specific hood
clearances. The surface of the entire back wall above the countertop and below the
hood must be covered with a non-combustible material such as metal, ceramic tile,
brick, marble or other stone.
16" Max.
18" Min.
22-3/4" Min.
46-1/4"
7/8"
*48"
2-1/2"
48"
8"
12" Minimum to
Adjacent Wall
12" Min.
Each Side
48" Minimum
to Combustibles
Non-
combustible
material**
** As defined in the National Fuel Gas Code (ANSI Z223.1/CSA B149.1, Current Edition).
Clearances from non-combustible materials are not part of the ANSI Z21.1/CSA 1.1 scope
and are not certified by CSA. Clearances less than 12" must be approved by local codes
and/or the authority having jurisdiction.
48"
47-7/8" Width
27-5/8" to
Front of
Bullnose
8-1/2" Height
Rangetop
1/2" Above Adjacent
Countertops
Control panel projects forwards from
standard depth cabinets.
Rangetop
1/2" Above Adjacent
Countertops
Front of deep cabinets can align with
control panel beveled edge.
16" Max.
18" Min.
22-3/4" Min.
46-1/4"
7/8"
*48"
2-1/2"
48"
8"
12" Minimum to
Adjacent Wall
12" Min.
Each Side
48" Minimum
to Combustibles
Non-
combustible
material**
** As defined in the National Fuel Gas Code (ANSI Z223.1/CSA B149.1, Current Edition).
Clearances from non-combustible materials are not part of the ANSI Z21.1/CSA 1.1 scope
and are not certified by CSA. Clearances less than 12" must be approved by local codes
and/or the authority having jurisdiction.
48"
47-7/8" Width
27-5/8" to
Front of
Bullnose
8-1/2" Height
Rangetop
1/2" Above Adjacent
Countertops
Control panel projects forwards from
standard depth cabinets.
Rangetop
1/2" Above Adjacent
Countertops
Front of deep cabinets can align with
control panel beveled edge.
8"
Countertop
Level
8-1/2"
Height
*23-5/8"
26-7/8"
To front of control panel
29-1/8"
To front of control knobs
27-5/8"
To front of bullnose
Rear finished edge of the
control panel
6-1/2"
1/2"
Countertop
Level
†
3/16"
11/32"
1-3/16"
1"
5-1/4"
To pipe
stub center
7-1/4"
** As defined in the National Fuel Gas Code (ANSI Z223.1/CSA B149.1, Current
Edition). Clearances from non-combustible materials are not part of the ANSI
Z21.1/CSA 1.1 scope and are not certified by CSA. Clearances less than 12" must
be approved by local codes and/or the authority having jurisdiction.