Spec Sheet

Ca
48" Professional Gas Rangetop
with 6 Burners and Griddle (Natural Gas)
CGU486P2MS1
For answers to your Café™ product questions, visit our website at cafeappliances.com.
WARRANTY
Parts warranty Limited 1-year entire appliance
Labor warranty Limited 1-year entire appliance
Warranty notes See written warranty for full details
DIMENSIONS AND INSTALLATION
Professional rangetops oer a number of choices in size and rangetop
configurations.
Backsplash Accessories: The rangetop requires a 12" minimum clearance
to a vertical combustible surface at the rear. A backsplash is required
for installations with less than 12" clearance. The following backsplash
accessories are available, or a custom, non-combustible backsplash
can be used.
UX12B36PSS, 12" backsplash
UXADJB36PSS, 36" backsplash with shelf
Backsplash with Warming Shelf: All Professional Hoods feature
infrared warming lights. The 30"-36" adjustable backsplash with warming
shelf is a perfect complement when installed with the tapered or
straight-sided hoods.
- Restaurant-Style Professional Hoods are shipped with a 22" stainless
steel backsplash and warming shelf.
Advance Planning for Professional Rangetops: Professional rangetops
oer a number of choices in size and rangetop configurations.
- All Professional rangetops are factory set for natural or liquid propane gas.
The correct model should be ordered for the installation situation.
Note: Conversion kits are included with the rangetop if the wrong gas type
was ordered. High Altitude kit, WB28K10553, is also available. The kits must
be installed by a qualified service technician at additional cost.
Electrical Requirements: Rangetops must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch circuit protected by a
15 amp circuit breaker or time-delay fuse.
Gas Supply:
- Natural gas models are designed to operate at 5" water column pressure.
For proper operation, the pressure of the natural gas supplied to the
regulator must be between 7” and 13” water column.
- The liquid propane models are designed to operate at 10" water column
pressure. For proper operation, the pressure of the LP source to the
regulator must be between 11” and 13” water column.
Rangetop
Control panel projects forwards from
standard depth cabinets.
Front of deep cabinets can align with control
panel beveled edge.
1/2" Above Adjacent
Countertops
Rangetop
1/2" Above Adjacent
Countertops
13" Max.
18" Min.
22 3/4" Min.
46 1/4"
7/8"
*48"
2 1/2"
48"
8"
12" Minimum to
Adjacent Wall
12" Min.
Each Side
48" Minimum
to Combustibles
Non-
combustible
material
8 1/2"
Height
27 1/2" to
Front of
Bullnose
47 7/8" Width
Rangetop
Control panel projects forwards from
standard depth cabinets.
Front of deep cabinets can align with control
panel beveled edge.
1/2" Above Adjacent
Countertops
Rangetop
1/2" Above Adjacent
Countertops
13
" Max.
18" Min.
22 3/4" Min.
46 1/4"
7/8"
*48"
2 1/2"
48"
8"
12" Minimum to
Adjacent Wall
12" Min.
Each Side
48" Minimum
to Combustibles
Non-
combustible
material
8 1/2"
Height
27 1/2" to
Front of
Bullnose
47 7/8" Width
Product Dimensions and Clearance:
A suitable overhead vent hood is required for models with a grill and
is recommended for all other models. Due to the high heat capacity of
this unit, particular attention should be paid to the hood and ductwork
installation to assure it meets local building codes.
Clearances between rangetop and side wall or combustible material must
be at least 12" on each side.
Allow 8" free space below the top surface of countertop. Allow additional
clearances below the burner box to install the regulator and make house
gas supply connections. Use a 90° elbow to route the gas connections and
limit interference with drawers or other cabinetry.
* The opening between a 4" high backsplash must be 36" to allow the
rangetop to slide back against the wall.
WARNING: Installations without a hood require 48" minimum to
combustibles above the rangetop. A custom hood installation with exposed
horizontal combustible surfaces must have an “auto-on” feature. Refer to
hood installation instructions for specific hood clearances. The surface of
the entire back wall above the countertop and below the hood must be
covered with a non-combustible material such as metal, ceramic tile, brick,
marble or other stone.