Specification
Café
™
36" Commercial-Style Gas Rangetop
with 6 Burners
CGU366P4TW2 / CGU366P2TS1 / CGU366P3TD1 (NATURAL GAS)
For answers to your Café™ product questions, visit our website at cafeappliances.com.
DIMENSIONS AND INSTALLATION
Commercial-Style rangetops oer a number of choices in size and
rangetop configurations.
Backsplash Accessories: The rangetop requires a 12" minimum clearance
to a vertical combustible surface at the rear. A backsplash is required
for installations with less than 12" clearance. The following backsplash
accessories are available, or a custom, non-combustible backsplash
can be used.
UX12BS36PSS, 12" backsplash
Backsplash with Warming Shelf: All Professional Hoods feature
infrared warming lights. The 30"-36" adjustable backsplash with
warming shelf is a perfect complement when installed with the tapered
or straight-sided hoods.
UXADBS36PSS, 30-36" backsplash with shelf
Advance Planning for Commercial-Style Rangetops: Commercial-Style
rangetops oer a number of choices in size and rangetop configurations.
All Commercial-Style rangetops are factory set for natural gas.
Note: A liquid propane conversion kit is included with the rangetop if the
wrong gas type was ordered. High Altitude Natural Gas, WB28X39728
and High Altitude LP, WB28X39729, are also available. The kits must be
installed by a qualified service technician at additional cost.
Electrical Requirements: Rangetops must be supplied with 120V,
60Hz, and connected to an individual, properly grounded branch circuit
protected by a 15 amp circuit breaker or time-delay fuse.
Gas Pressure Regulator:
You must use the gas pressure regulator supplied with this rangetop. For
proper operations the inlet pressure to the regulator should be as follows:
Natural Gas: Minimum pressure: 6” of Water Column / Maximum pressure:
13” of Water Column
Propane (LP) Gas: Minimum pressure: 11” of Water Column / Maximum
pressure: 13” of Water Column
See installation instructions for more details
Product Dimensions and Clearance:
A suitable overhead vent hood is required for models with a grill and
is recommended for all other models. Due to the high heat capacity of
this unit, particular attention should be paid to the hood and ductwork
installation to assure it meets local building codes.
Clearances between rangetop and side wall or combustible material must
be at least 12" on each side.
Allow 8" free space below the top surface of countertop. Allow additional
clearances below the burner box to install the regulator and make house
gas supply connections. Use a 90° elbow to route the gas connections and
limit interference with drawers or other cabinetry.
* The opening between a 4" high backsplash must be 36" to allow the
rangetop to slide back against the wall.
WARNING: Installations without a hood require 48" minimum to
combustibles above the rangetop. A custom hood installation with
exposed horizontal combustible surfaces must have an “auto-on” feature.
Refer to hood installation instructions for specific hood clearances. The
surface of the entire back wall above the countertop and below the hood
must be covered with a non-combustible material such as metal, ceramic
tile, brick, marble or other stone.
** As defined in the National Fuel Gas Code (ANSI Z223.1/CSA B149.1, Current Edition).
Clearances from non-combustible materials are not part of the ANSI Z21.1/CSA 1.1 scope
and are not certified by CSA. Clearances less than 12" must be approved by local codes
and/or the authority having jurisdiction.
**
35-7/8" Width
27-5/8" to
Front of
Bullnose
8-1/2"
Height
Rangetop
1/2" Above Adjacent
Countertops
Control panel projects forwards from
standard depth cabinets.
Rangetop
1/2" Above Adjacent
Countertops
Front of deep cabinets can align with
control panel beveled edge.
** As defined in the National Fuel Gas Code (ANSI Z223.1/CSA B149.1, Current Edition).
Clearances from non-combustible materials are not part of the ANSI Z21.1/CSA 1.1 scope
and are not certified by CSA. Clearances less than 12" must be approved by local codes
and/or the authority having jurisdiction.
**
35-7/8" Width
27-5/8" to
Front of
Bullnose
8-1/2"
Height
Rangetop
1/2" Above Adjacent
Countertops
Control panel projects forwards from
standard depth cabinets.
Rangetop
1/2" Above Adjacent
Countertops
Front of deep cabinets can align with
control panel beveled edge.
** As defined in the National Fuel Gas Code (ANSI Z223.1/CSA B149.1, Current Edition).
Clearances from non-combustible materials are not part of the ANSI Z21.1/CSA 1.1
scope and are not certified by CSA. Clearances less than 12" must be approved by
local codes and/or the authority having jurisdiction.