Installation Guide
8 31-11072-2
Installation Instructions
INSTALLATION—ELECTRICAL CONNECTIONS
CHECKLISTS
GROUNDING INSTRUCTIONS:
The ground wire in the conduit is connected to the 
cooktop frame. Effective January 1, 1996, the National 
Electrical Code will not permit grounding through neutral. 
If used in new construction after January 1, 1996 or in a 
mobile home, recreational vehicle or if local codes do not 
permit grounding through the neutral white lead, attach 
the appliance grounding lead (green or copper) to the 
residence grounding conductor (green or bare copper) 
in accordance with local codes. When connecting to a 3 
conductor branch circuit, if local codes permit, connect 
the ground connector lead of the cooktop to the branch 
circuit neutral (gray or white in color).
WARNING
 If the cooktop is being installed into a 
blind counter (one with no cabinet opening below), wire 
connections must be made before putting the cooktop 
into the cutout opening.
1
 PRE-TEST CHECKLIST
A
 Remove all protective film, if present, and any 
stickers.
B
 Check to be sure that all wiring is secure and not 
pinched or in contact with moving parts.
C
 Check level of appliance.
D
 Check that the cooktop is properly grounded.
NOTE TO ELECTRICIAN: The power leads 
supplied with this appliance are UL recognized for 
connections to larger gauge household wiring. The 
insulation of these leads is rated at temperatures 
much higher than the temperature rating of 
household wiring. The current carrying capacity 
of a conductor is governed by the wire gauge 
and also the temperature rating of the insulation 
around the wire.
NOTE: ALUMINUM WIRING
A.   
WARNING
 IMPROPER CONNECTION OF 
ALUMINUM HOUSE WIRING TO THE COPPER 
LEADS CAN RESULT IN AN ELECTRICAL 
HAZARD OR FIRE.
B.   Splice copper wires to aluminum wiring using 
special connectors designed and UL approved 
for joining copper to aluminum, and follow 
the manufacturer’s recommended connector 
procedure closely.
NOTE: Wire used, location and enclosure of 
splices, etc., must conform to good wiring 
practice and local codes.
2
 OPERATION CHECKLIST
A
 Remove all items from the top of the cooktop 
surface.
B
 Turn on the power to the cooktop (refer to your 
Owner’s Manual). Verify that all surface burners 
operate properly.
C
 Check that the circuit breaker is not tripped nor 
the house fuse blown.
D
 Check that conduit is securely connected to the 
junction box.