Specification Sheet
Café
™
 21.3 Cu. Ft. Smart Built-In  
Bottom-Freezer Refrigerator
CDB36LP2PS1 
SIDE PANELS
Side panels (not supplied) must be used whenever the sides of the 
refrigerator will be exposed. The 1/4" side panels will slip into the 
side case trim. Order side panels from your cabinet manufacturer. 
* Depending on installation height.
FLOORING 
For proper installation, this refrigerator must be placed on a level 
surface of hard material that is at the same height as the rest of the 
flooring. This surface should be strong enough to support a fully 
loaded refrigerator, or approximately 1500 lbs.
NOTE: Protect the finish of the flooring. Cut a large section of the 
cardboard carton and place under the refrigerator where you are working.
WATER AND ELECTRICAL LOCATIONS 
The opening must be prepared with the electrical and water 
supply located as shown.
THE CUTOUT DEPTH MUST BE 24" 
The refrigerator will project forward, slightly beyond adjacent 
cabinets, depending on your installation.
ADDITIONAL SPECIFICATIONS 
A 120 volt, 60Hz, 15 or 20 amp power supply is required. An 
individual properly grounded branch circuit or circuit breaker is 
recommended. 
Install a properly grounded 3-prong electrical receptacle recessed  
into the back wall. Electrical must be located on rear wall as 
shown. 
NOTE: GFI (ground fault interrupter) is not recommended. Water line can enter 
the opening through the floor or rear wall. The water line installed should be 
1/4" O.D. copper tubing or GE SmartConnect™ tubing between the cold water 
line and water connection location. The line should be long enough to extend 
to the front of the refrigerator. Installation of an easily accessible shuto valve 
in the water line is required.
CDB36LP2PS1 / CDB36RP2PS1
Use two 
additional hole 
locations at 
end of 
brackets
Wall
Studs
Bracket 
mounted
into vertical 
wall studs
C
Ensure holes
selected are
centered on
the studs
L
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET
35 1/2"
 (90.2)
2 5/16"
(5.9)
*84 
+
- 
.500
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75"
(190.5 )
From floor
to bottom
of electrical
area
SIDE VIEWFRONT VIEW
ELEC.
6"
(15.2)
10"
(25.4)
23 5/8" (60)
2 3/8"
(6)
4 7/16"
(11.3)
7/16
"
 (1.1)
Trim overlap
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
WATER
5"
(12.7)
5"
(12.7)
3 1/2"
(9.0)
WATER
10" (25.4)
81 1/2"
(207.0)
2 9/16"
(6.5)
*3"- 4"
(7.6 - 10.2)
*Depending
on installation
height
1 7/8"
(4.8)
24" (61.0)
3/16"
(.5)
*84"
(213.4)
*Depending
on installation
height
CDB36LP2PS1 / CDB36RP2PS1
DIMENSIONS AND INSTALLATION