Specification Sheet
Café
™
21.3 Cu. Ft. Smart Built-In
Bottom-Freezer Refrigerator
CDB36LP2PS1
SIDE PANELS
Side panels (not supplied) must be used whenever the sides of the
refrigerator will be exposed. The 1/4" side panels will slip into the
side case trim. Order side panels from your cabinet manufacturer.
* Depending on installation height.
FLOORING
For proper installation, this refrigerator must be placed on a level
surface of hard material that is at the same height as the rest of the
flooring. This surface should be strong enough to support a fully
loaded refrigerator, or approximately 1500 lbs.
NOTE: Protect the finish of the flooring. Cut a large section of the
cardboard carton and place under the refrigerator where you are working.
WATER AND ELECTRICAL LOCATIONS
The opening must be prepared with the electrical and water
supply located as shown.
THE CUTOUT DEPTH MUST BE 24"
The refrigerator will project forward, slightly beyond adjacent
cabinets, depending on your installation.
ADDITIONAL SPECIFICATIONS
A 120 volt, 60Hz, 15 or 20 amp power supply is required. An
individual properly grounded branch circuit or circuit breaker is
recommended.
Install a properly grounded 3-prong electrical receptacle recessed
into the back wall. Electrical must be located on rear wall as
shown.
NOTE: GFI (ground fault interrupter) is not recommended. Water line can enter
the opening through the floor or rear wall. The water line installed should be
1/4" O.D. copper tubing or GE SmartConnect™ tubing between the cold water
line and water connection location. The line should be long enough to extend
to the front of the refrigerator. Installation of an easily accessible shuto valve
in the water line is required.
CDB36LP2PS1 / CDB36RP2PS1
Use two
additional hole
locations at
end of
brackets
Wall
Studs
Bracket
mounted
into vertical
wall studs
C
Ensure holes
selected are
centered on
the studs
L
FRONT VIEW OF CUTOUT
WITH ANTI-TIP BRACKET
35 1/2"
(90.2)
2 5/16"
(5.9)
*84
+
-
.500
(212.1-214.6)
*Trim will overlap
additional 7/16"
3 1/2"
(8.9)
75"
(190.5 )
From floor
to bottom
of electrical
area
SIDE VIEWFRONT VIEW
ELEC.
6"
(15.2)
10"
(25.4)
23 5/8" (60)
2 3/8"
(6)
4 7/16"
(11.3)
7/16
"
(1.1)
Trim overlap
SIDE VIEW INSTALLED
WITH ANTI-TIP BRACKET
WATER
5"
(12.7)
5"
(12.7)
3 1/2"
(9.0)
WATER
10" (25.4)
81 1/2"
(207.0)
2 9/16"
(6.5)
*3"- 4"
(7.6 - 10.2)
*Depending
on installation
height
1 7/8"
(4.8)
24" (61.0)
3/16"
(.5)
*84"
(213.4)
*Depending
on installation
height
CDB36LP2PS1 / CDB36RP2PS1