Technical Information Manual Revision n.5 2 May 2005 MOD. A 1732 - A 1832 HIGH VOLTAGE BOARDS MANUAL REV.5 NPO: 00101/00:17XXx.
CAEN will repair or replace any product within the guarantee period if the Guarantor declares that the product is defective due to workmanship or materials and has not been caused by mishandling, negligence on behalf of the User, accident or any abnormal conditions or operations. CAEN declines all responsibility for damages or injuries caused by an improper use of the Modules due to negligence on behalf of the User.
Document type: User's Manual (MUT) Title: Mod. A1732-A1832 High Voltage Boards Revision date: 02/05/2005 Revision: 5 TABLE OF CONTENTS 1. 2. 3. INTRODUCTION.........................................................................................................................................................3 1.1 THE CAEN UNIVERSAL MULTICHANNEL POWER SUPPLY SYSTEM ...........................................................................3 1.2 TECHNICAL SPECIFICATIONS TABLE OF THE SY 1527 SYSTEM .
Document type: User's Manual (MUT) Title: Mod. A1732-A1832 High Voltage Boards Revision date: 02/05/2005 Revision: 5 LIST OF FIGURES FIG. 2.1 – MOD. A 1732 – A 1832 (LEFT) AND MOD. A 1732B – A 1832B (RIGHT) FRONT PANEL ...................9 FIG. 4.1 – A) MOD. A1732 - A 1832 SIDE VIEW; B) MOD. A1732B - A 1832B TOP VIEW .....................................16 FIG. 4.2 – FULL SCALE RANGE DIP-SWITCH TOP VIEW ....................................................................................................
Document type: User's Manual (MUT) Title: Mod. A1732-A1832 High Voltage Boards Revision date: 02/05/2005 Revision: 5 1. Introduction 1.1 The CAEN Universal Multichannel Power Supply System The SY 1527 system is the fully equipped, large scale experiment version of a new line of power supply systems which represent CAEN's latest proposal in the matter of High Voltage and Low Voltage Power Supplying.
Document type: User's Manual (MUT) Title: Mod. A1732-A1832 High Voltage Boards Revision date: 02/05/2005 Revision: 5 electronics can be anyway remotely controlled by single boards which are inserted in the SY 1527 mainframe and act as branch controllers. Fast, accurate set-up and monitoring of system parameters (14-bit resolution on Voltages and Currents with standard boards) is available for each branch controller thanks to the use of one microprocessor per slot.
Document type: User's Manual (MUT) 1.2 Title: Mod. A1732-A1832 High Voltage Boards Revision date: 02/05/2005 Revision: 5 Technical Specifications Table of the SY 1527 system Table 1.1 - Technical specifications of the SY 1527 mainframe: general Packaging - 19"-wide, 8U-high Euro-mechanics rack; - Depth: 720 mm. Weight -Mainframe (*): 24 kg -Mod. A1532: 3.2 kg Voltage range: 100/230 V Power requirements Frequency: 50/60 Hz Power: 3400 W Max. number of boards per crate 16 Max.
Document type: User's Manual (MUT) Title: Mod. A1732-A1832 High Voltage Boards Revision date: 02/05/2005 Revision: 5 2. Mod. A 1732 - A 1832 HV Boards 2.1 Functional description The Mod. A 1732 – A 1832 are single width boards housing 12 H.V. channels with either positive (A 1732P – A 1832P) or negative (A 1732N – A 1832N) polarity. 28 channel double width versions (Mod. A 1732B – A 1832B) are available as well, with either positive (A 1732BP – A 1832BP) or negative polarity (A 1732BN – A 1832BN).
Document type: User's Manual (MUT) 2.2 Title: Mod. A1732-A1832 High Voltage Boards Revision date: 02/05/2005 Revision: 5 Channel Characteristics Table Table 2.1 - Channel characteristics of the Mod. A 1732 / 1732B - A 1832 / 1832B HV Boards Positive / Negative depending on purchased version Polarity: Output Voltage: 0÷6 kV low range 200 μA (Mod. A 1832 - A 1832B) Max. Output Current: high range 1 mA Voltage Set/Monitor Resolution: 500 mV 100 nA (Mod.
Document type: User's Manual (MUT) Threshold TMAX): 2.3 Title: Mod. A1732-A1832 High Voltage Boards temperature parameters (TMIN, Revision date: 02/05/2005 Revision: 5 +5 ÷ +65 °C Front Panel NPO: 00101/00:17XXx.MUTx/05 Filename: A1732B-A1832B_REV5.
Document type: User's Manual (MUT) Title: Mod. A1732-A1832 High Voltage Boards Revision date: 02/05/2005 Revision: 5 Mod. V560E Mod. V560E Mod. A1832BP Mod.
Document type: User's Manual (MUT) 2.4.1 Title: Mod. A1732-A1832 High Voltage Boards Revision date: 02/05/2005 Revision: 5 Packaging The Mod. A 1732 – A 1832 modules are housed in a 5 TE-wide, 6U-high mechanics. The Mod. A 1732B – A 1832B modules are housed in a 10 TE-wide, 6U-high mechanics. 2.4.2 External connections The location of all components of the front panel is shown in Fig. 2.1, p. 8.
Document type: User's Manual (MUT) Title: Mod. A1732-A1832 High Voltage Boards Revision date: 02/05/2005 Revision: 5 Type: red LED for positive polarity version; yellow LED for negative polarity version 2.4.4 Other components VMAX trimmer: NPO: 00101/00:17XXx.MUTx/05 Filename: A1732B-A1832B_REV5.DOC Function: it allows to adjust the hardware maximum voltage VMAX common to all the channels. Its value can be read out via software.
Document type: User's Manual (MUT) Title: Mod. A1732-A1832 High Voltage Boards Revision date: 02/05/2005 Revision: 5 3. Safety information and installation requirements 3.1 General safety information This section contains the fundamental safety rules for the installation and operation of the boards. Read thoroughly this section before starting any procedure of installation or operation of the product. 3.1.
Document type: User's Manual (MUT) 3.2 Title: Mod. A1732-A1832 High Voltage Boards Revision date: 02/05/2005 Revision: 5 Safety Terms and Symbols on the Product These terms may appear on the product: • DANGER indicates an injury hazard immediately accessible as you read the marking. • WARNING indicates an injury hazard not immediately accessible as you read the marking. • CAUTION indicates a hazard to property including the product. The following symbols may appear on the product: 3.
Document type: User's Manual (MUT) Title: Mod. A1732-A1832 High Voltage Boards Revision date: 02/05/2005 Revision: 5 4. Operating modes The Mod. A 1732 – A 1832 and A 1732B – A 1832B boards can be controlled, either locally or remotely, through the SY 1527 software interface. For details on SY 1527 system operation, please refer to the User's Manual of this product. The following sections contain a description of commands available for the board control and status monitoring. ATTENTION THE MOD.
Document type: User's Manual (MUT) • • • • • Title: Mod.
Document type: User's Manual (MUT) Title: Mod. A1732-A1832 High Voltage Boards Revision date: 02/05/2005 Revision: 5 T A BC Dip Switch (side view) 4 3 2 1 A) Out 0 Out 1 Out 2 Channels Channels Channels Out 3 Out 4 Out 5 Controller Out 6 Out 7 Out 8 Channels Channels Channels Out 9 Out 10 Out 11 Dip Switch T A BC 4 3 2 1 B) Channels Channels Channels Channels Channels Channels Channels Fig. 4.1 – A) Mod. A1732 - A 1832 side view; B) Mod.
Document type: User's Manual (MUT) Title: Mod. A1732-A1832 High Voltage Boards Revision date: 02/05/2005 Revision: 5 (FSR = 6 kV / 1 m A) 1 2 3 PCB 4 on Dip-switch 2 = ON Dip-switch 1, 3, 4 = OFF (FSR = 6 kV / 200 μ A) 1 PCB 2 3 4 on Dip-switch 1, 2, 3, 4 = OFF FRONT PANEL Fig. 4.2 – Full scale range dip-switch top view NPO: 00101/00:17XXx.MUTx/05 Filename: A1732B-A1832B_REV5.
Document type: User's Manual (MUT) Title: Mod. A1732-A1832 High Voltage Boards Revision date: 02/05/2005 Revision: 5 APPENDIX A Notes for Mod. A1832 E Each A1832 E channel is provided with an "HV EN" input (on the right side of the SHV connector) that disables the channel when the two pins are not shorted (jumper removed). upper pin HV EN ch. i 1 kΩ VCC 100 kΩ to CONTROL LOGIC (TTL) 0=ENABLED 100 nF Fig. A.1 – Mod.