User Guide

Table Of Contents
-e Aperture Emulation on
-e+ ditto
-e- Aperture Emulation off
Flag options (e.g. -e) can be used without repeating the
‘-’ character:
-eatm Aperture emulation on, annulus and thermal
emulation on, mirror output
-ea-t+ Aperture emulation on, NO annulus
emulation, thermal emulation on
Defining tolerance values:
If there is no sign, the value applies to either direc
-
tion,
+ signifies a positive tolerance,
- a negative tolerance.
-D0.10 adjusts the draw tolerance to 610%
-D+0.1 -D-0.05 adjusts the draw tolerance
to +10% and -5%
Notesontheindividualoptions:
-D DrawTolerance(0.1=10%):
Default:0
-E DrillTolerance(0.1=10%):
Default:0
-F FlashTolerance(0.1=10%):
Default:0
-N Supressmessages:
Thisoptionsupresseswarningsorotherinformation
intheconsolewindow(DOSbox,Linuxconsole).
ThusCAMjobsrunwithoutinterruption.
Default:off
-O Route-Optimizing:
Withthisoptiontheroute-optimizingfortheplottercan
beturnedonandoff.
Default:on
-P PlotterPen(layer=pen):
If you use a color pen plotter, you can determine which layer
istobedrawninwhichcolor.
Example:-P1=0-P15=1
-R DrillRackFile:
Withthisoptionyoudefinethepathtoafilewiththedrill
configurationtable.
237