User Guide
Masks
Settings for the overmeasure of the solder stop mask (Stop) and the sol
-
dercreammask(Cream)aremadehere.
DesignRules:SettingsforSolderStopandCreamFrame
The default value for solder stop is 4 mil, i.e. minimum value is maxi
-
mumvalueis4mil.Thepercentvaluehasnoeffectinthiscase.
The value for the cream frame is set to 0, which means that it has the
samedimensionsasthesmd.
If values are given in percent, in the case of smds and pads of the form
Long or Offset, the smaller dimension is the significant one. The values
areconstrainedbyminimumandmaximumvalues.
The value for Cream is given positively, as is Frame, although its effect is
toreducethesizeofthe soldercreammask(creamframe).
The solder cream mask is only generated for SMDs, and is displayed on
layer 31, tCream, or layer 32, bCream. The solder stop mask is drawn in
layers29, tStop,or30, bStop.
Setting the flag STOP or CREAM (only for SMD) to OFF for a pad or
smd at the package definition forbids EAGLE to generate a solder stop
maskoracreamframeforit.
Limit determines, together with the hole diameter, whether or not a via
istobecoveredwithsolderstoplacquer.
Example:
Limit = 24: All through-plated holes with diameters up to 24 mil are
lacquered (no solder stop symbol), but vias with larger hole diameters
receiveasolderstopsymbol.Thissettingdoesnotaffectpads!
If the STOP flag for the via is set (CHANGE STOP ON) EAGLE
won'tgenerateasolderstopmaskforit.