Model: AppleAiro Dehumidifier INSTALLATION, OPERATION & SERVICE INSTRUCTIONS
MANUAL INDEX CAUTIONARY WARNING ………………………………… Page 1 WARNING ………………………………………………… Page 1 INTRODUCTION ………………………………………… Page 2 ELECTRICAL SUPPLY …………………………………… Page 2 SPECIFICATIONS ………………………………………… Page 2 INSTALLATION AND OPERATION GUIDE ……………… Page 2 OPERATION ……………………………………………… Page 3 MAINTENANCE ………………………………………… Page 6 WIRING DIAGRAM ……………………………………… Page 7 BUMPER TO BUMPER WARRANTY……………………… Page 8 BENEFITS OF CADPXS WARRANTY …………………… Page 8 WARRANTY REGISTRATION …………………………… Page 8
CAUTIONARY WARNING • The appliance is not being used above the elevation level of over 2000 m (6562 ft.) • The appliance is only designed to be USED INDOORS. • If being used in a wet area, plug it into a GROUND FAULT INTERRUPTER. • DO NOT use the appliance as a bench or table. • The appliance must always be used in a horizontal position. WARNING Read the operation and maintenance instructions carefully before using this unit.
INTRODUCTION Claiming to be the World’s Most Powerful Dehumidifier for its Size, the AppleAiro sure promises to deliver a lot in its small size. This machine can eliminate any kind of musty odors or dampness in your crawl space by drying and filtering the air. It is highly efficient, it can provide an extraordinary performance of around 85 pints per day capacity and can over 2,300 sq,ft of dry air per minute in the room where it is kept.
Drain Hose Installation 1.Attach the hose inlet to the drain outlet located on the graph appliance. 2.Allow the hose to be set off to a drain or a sink or even to a container that can collect the discharged water. OPERATION 1.1.Plugged in - Shutdown Mode When plugged in, the display will communicate to the user thatthe machine is in Shutdown mode and ready to be powered on. 1.2.
1.4.Navigation Press the key to advance to the next screen . Press the key to scroll through available values . 1.5.Purging Press the button to purge the machine. The display will communicate to the user that the machine is purging. The last line of the control panel display “DRAINING”. This will momentarily replace float switch until the machine has finished purging. Work cycle lasting 14 seconds. While in Humidistat Mode, When the water level reaches, the unit will drain automatically.
1.9.Continuous dehumidifying Mode The default mode is continuous dehumidifying Mode “On”. Press the Set button to toggle the continuous dehumidifying Mode On/Off. If the continuous mode “off”, the humidistat mode is automatically turned on, and then the humidistat set point is entered for operation. The display will communicate to the user that the machine is continuously dehumidifying on the last line of the dashboard. The set value shows “CO”. 1.10.
Solution: Verify that the pump is properly installed and functioning. If so, unplug the unit for two minutes, then restart. LO: Room Temperature is below 33.8℉ Solution: Increase the room temperature so it is within operation range (above 33.8℉). If error is still displayed, check the sensor. HI: Room Temperature is above 104℉ Solution: Decrease the room temperature so it is within operating range (below 104℉). If error is still displayed, check the sensor.
WIRING DIAGRAM 7
BUMPER TO BUMPER WARRANTY By choosing CADPXS, you will be sure that you have a commercial-grade dehumidifier that will perform the job it is designed for. These are state of the art dehumidifiers that are backed with a bumper to bumper warranty. BENEFITS OF CADPXS WARRANTY A CADPXS bumper-to-bumper warranty covers the entire product and accessories, electrical parts and components, safety equipment and instruments. It does not cover parts of the product that wear and tear with time.
2550 N LOOP FWY #108 HOUSTON TX 77092 (888) 928-1380 (Monday-Friday: 08:00AM – 5:00PM) UTC sales@cadpxs.com www.cadpxs.