User's Manual

7
User button SLEEP->WAKE
Initialize Activation Count
Used to initialize the soap usage
level to 0 when doing a soap
refill
Explanation: Activation Count (soap level) will be maintained until the user physically initiates a
WAKE->SLEEP->WAKE sequence using the User button. Or else, the Activation Count remains.
START
WAKE mode
User button
>5sec?
SLEEP mode
Save Activation
Count
Reset Activation
Count
User button
>5sec?
END
Y Y
N
N
Action
Logic
Description
Reset button pressed
Initialize Tx count, Battery Level
Used to initialize parameters
when a fresh battery is installed
Explanation: Reset button is only accessible when changing the battery. By changing the battery,
followed by pressing the Reset button, the tag resets the Tx Count and Battery level.