Troubleshooting guide

Installation Instructions
How do I install for
new construction?
Figure 1
Face of wall can must
extend
1
/2" from face of stud
to allow for sheetrock.
The C Series REQUIRES a minimum distance of 6"
from adjacent surfaces and 0" from the floor and
the CT Series requires a minimum distance of 4
1
/2"
from adjacent surfaces and 0" from the floor.
However, Cadet RECOMMENDS 12" from all
adjacent surfaces and 12" above the floor for
longer and cleaner performance. Heaters must be
spaced at least 3 feet apart.
Model C: Secure the wall can to the stud with 2
screws (See Figures 1 & 2). As an option, the
rubber shim provided may be attached to side of
wall can to square the wall can to the stud.
Model CT: Secure the wall can to studs on both
sides with 4 screws.
STEP 1
Mount The Wall Can
How do I install in
an existing wall?
Model C: Cut a hole 8" wide by 10
1
/
4" high next to
wall stud. The C Series REQUIRES a minimum
distance of 6" from adjacent surfaces and 0" from
the floor. However, Cadet RECOMMENDS 12" from
all adjacent surfaces and 12" from the floor (See
Figure 4).
Model CT: Cut a hole 14
3
/
4" wide by 10
1
/
4" high next
to wall stud. The CT Series REQUIRES a minimum
distance of 4
1
/2" from adjacent surfaces and 0" from
the floor. However, Cadet RECOMMENDS 12" from
all adjacent surfaces and 12" from the floor (See
Figure 5).
STEP 1
Cut Hole In Wall
Route supply wire from circuit breaker to thermo-
stat to heater. For models with built-in thermostat,
route supply wire from circuit breaker to heater.
Remove a knockout and attach the supply wire
with a strain relief connector leaving 10" wire lead
for later use. Connect supply ground wire to
grounding pigtail in wall can (See Figure 3).
Proceed to PART TWO.
STEP 2
Connect Supply Wires
Route supply wire from circuit breaker to thermo-
stat to heater. For models with built-in thermostat,
route supply wire from circuit breaker to heater.
Remove a knockout and attach the supply wire with
a strain relief connector leaving 10" wire lead for
later use (See Figure 3). Connect supply ground
wire to grounding pigtail in wall can.
STEP 2
Connect Supply Wires
Insert wall can into opening. Keeping wall can flush
with wall, secure model C to wall stud with 2
screws and model CT to both wall studs with 4
screws. Proceed to PART TWO.
Mount Wall Can
Figure 2
Attach wall can to stud with
screws.
(Model C shown)
Figure 3
Figure 4
Model C
READ ALL
INSTRUCTIONS
AND SAFETY
INFORMATION
IMPORTANT!
It is extremely
important you
verify that the
electrical supply
wires ar
e the same
voltage as the
heater (i.e. 120 volt
heater to 120 volt
power supply and
240 volt heater to
240 volt power
supply). If
replacing an
existing heater,
check the labels of
the old heater and
replace using the
same voltage.
Hooking a 240 volt
heater to a 120 volt
power supply will
drastically reduce
the heater's output.
Hooking a 120 volt
heater to a 240 volt
power supply will
destroy the heater.
Connecting your
heater to an
incompatible
power supply will
void the warranty.
Part One
PLACEMENT: Install The Com-Pak Plus (Model C) vertically (recommended) or horizontally. Model C may be
installed in the ceiling (for models up to 1500W maximum). The Com-Pak Twin Plus (Model CT) must be
installed vertically.
THERMOSTAT:
A thermostat is required for models without a built-in thermostat. A Cadet Electronic
Thermostat (T4700 or T4800) or Cadet Dual Diaphragm Thermostat (T4398) is recommended for ultimate control
and comfort.
Figure 5
Model CT
STEP 3