Technical information
WATTS AMPS
◆
31
Ordering Information:
Model CEH005-P (1 Phase) is designed to use a C600M, C600S or a CEKTB2
thermostat. If you add the jumpers, as shown on the heater wiring diagram
(supplied with instructions and in wiring compartment) you can use a
Single Pole 22 amp wall stat or a CEKTB1 thermostat. USE ONLY C600M,
C600S, OR A CEKTB2 FOR 3 PHASE hookup on this model.
Approximate air throw is 12’. The CEH is recomm
ended for elevations under
7500 feet.
Architectural Information:
Fan forced unit heater shall be UL listed and dual rated at 208, 240 volts.
Horizontal or vertical mounting shall be possible to direct discharged air.
External cabinet shall be constructed of 20 gauge high quality steel. All
metal surfaces of the cabinet, external and internal, shall be finished with
a baked on powder coat paint system.
Fan shall be aluminum blade axial
flow type, and mounted directly to the motor shaft. Motor shall be shaded
pole, industrial rated, with an inherent overheating protection device.
Heating elements shall be sealed in magnesium oxide powder and protected
by metal sheathing, over which aluminum fins are applied. Heater shall be
equipped with manual reset thermal cut out for over temperature protection.
Fan
motor circuit shall be thermostatically controlled, allowing fan to
remain operating after the elements have shut off, discharging the residual
element heat. Wiring compartment shall have convenient access door with
captured hardware.
Part# Model# Description Phase 240V 208V 240V 208V Wt./Lbs
027418 09265 6 CEH005-P Unit Heater 1/3 5,000 3,750 20.80 18.00 24
Part# Model# Description Wt./Lbs
027418 09282 3 CEKV1 AirVane (louver) Kit 1
027418 09610 4 CEKTB1* Single Pole Field Mount Thermostat .44
027418 09615 9 CEKTB2* 2 Stage Field Mount Thermostat .69
027418 09660 9 CEKM1 Ceiling Hat Bracket 1.35
027418 09670 8 CEKWM Wall Hanger Arm (Also requires CEKM1) 4.7
Specifications CEH005
CFM 350
FPM 940
Temp. Rise (ºF) 45º
Motor HP 1/70
Motor RPM 1600
Recommended Spacing (ft.) 12
UPC Code
UPC Code
PHONE 360.693.2505
FAX 360.694.8668
WEB www.cadetco.com
CEKWM
Wall Hanger Arm
(Requires CEKM1)
CEKM1
Ceiling Hat Bracket
The CEH Series
ACCESSORIES
*Thermostat kit maximum temperature range 110˚F