The Cadet Electric Baseboard The Register Plus The Com-Pak Plus The Com-Pak Twin Plus The Com-Pak Bath Cadet Manufacturing Electric Heating Products Product Catalog NEW FEATURE! Learn more about the Cadet products on each page - just SCAN with your digital device! www.cadetco.
Dear Friends: IT WAS 1953 WHEN MY WIFE AND I LEFT NORTH DAKOTA TO PURSUE THE OPPORTUNITIES OF A LIFE IN THE WEST. WE FIRST SETTLED IN OLYMPIA WASHINGTON. OLYMPIA IS WHERE WE HAD OUR FIRST we were excited about the comfort and affordability provided by zonal heating. EXPOSURE TO ELECTRIC HEATING, AND We opened a small sales operation in August of 1955. Although the store was very successful, we sold it in February of 1956.
Cadet Manufacturing Electric Heating Products ZONAL HEATING BENEFITS ................................5-7 HEAT SELECTION TIPS ...........................................8 FAN FORCED HEATERS .........................................9-25 The Register Plus .............................................................9-10 The Com-Pak Max ...........................................................11-12 The Com-Pak Plus ...........................................................13-14 The Com-Pak Twin Plus .......
From our President Dear Valued Customers: The term “Valued Customer” has never meant as much as it means today to business. In a dynamic and challenging market place, every customer is indeed very valued. Even though Cadet has been in business for over fifty years, each customer we serve is important to our future. That is why we challenge ourselves to provide proactive service that answers each customer’s specific needs, and do it with a smile.
Zonal Heat Solutions ◆ Whether it’s for New Construction, a Remodel or Addition, or Hybrid Heating ZONAL HEATING CONTINUES TO IMPROVE COMFORT & SAVE ENERGY Central systems are like having one light switch for the whole house, “on or off”. Why heat rooms you’re not using? With Cadet heaters, no heat is lost through ductwork or exhaust: 100% of the electricity consumed is converted to heat.
◆ 6 New Construction Zonal Electric Heat saves costs during construction, and saves energy for the life of the home. Heating System Comparisons Comparison Assumptions • 1800 Square Foot Home • Winter: Oct 1 - Mar 1 • 3 Bedrooms, 2.
◆ Remodel or Addition Electric Zonal Heat is a perfect solution for remodels or room additions. Installation is fast, easy, and economical with no ductwork required. 1 2 3 CHALLENGE: New room addition requires new ductwork for heating, balancing of the new air flow, and possible resizing of the existing furnace. SOLUTION: Electric heat installation is low cost, easy installation.
◆ 8 Heater and Thermostat Selection Tips Heater Selection Tips KNOW YOUR VOLTAGE KNOW YOUR WATTAGE Before buying the heater of your choice, you must know the voltage at connection. You must know whether you have 120 volt or 240 volt power supply. Step 1: Age of Home Select column with age of your home - A heat loss calculation should be performed if your home falls outside of these standards.
The Register Plus ◆ 9 The premier choice for all rooms SAFETY High temperature manual reset: turns off heater if normal operating temperatures are exceeded QUALITY Powder coat paint process eliminates sharp metal edges EASY Wall can designed for quick installation with mounting legs that minimize measuring time COMFORT Commercial grade steel element is quiet and efficient General Information: The Register Plus is Cadet’s premier fan forced heater line and is often chosen for its similar appearance to
◆ 10 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.com Technical Information: A thermostat is required. For optimum comfort use a Cadet electronic thermostat. Fan heaters and thermostats work best when installed on an inside wall. A double pole, built-in thermostat may be installed in the field. UL requires heater to be placed a minimum distance of 6” from adjacent surfaces and 4.5” from the floor. Manufacturer recommends installation of 12” from all surfaces.
◆ The Com-Pak Max 11 The professional’s choice for smaller areas SAFETY Thermal Safeguard - High temperature manual reset: turns off heater if normal operating temperatures are exceeded QUALITY • • Durable steel tube and plate constructed heating element Powder coat paint process eliminates sharp metal edges CONVENIENCE • • Horizontal or vertical grill mounting options Multi-watt versatility EASY Wall can designed for ease of installation General Information: The Com-Pak Max provides all the bene
◆ 12 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.com NOTE: Manufacturer recommends installing heater assembly after walls are finished. Heater must be cleaned every six months minimum. Technical Information: The wall can and the Com-Pak Max heater assembly may be installed vertically or horizontally. The Com-Pak Plus grill may be installed vertically or horizontally. The Com-Pak Max register style grill may only be installed horizontally.
The Com-Pak Plus ◆ 13 The economical choice for smaller areas SAFETY Primary and Secondary Thermal Safeguards - Robust, heavy duty high temperature manual power reset - Over temperature one-time thermal fuse QUALITY • Nichrome coil element for quick heat • Powder coat paint process eliminates sharp metal edges EASY Wall can designed for ease of installation CONVENIENCE • Horizontal or vertical grill mounting options • With or without built-in thermostat General Information: The Com-Pak Plus is
◆ 14 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.
The Com-Pak Twin ◆ 15 The economical choice for larger areas SAFETY Primary and Secondary Thermal Safeguards - Robust, heavy duty high temperature manual power reset - Over temperature one-time thermal fuse QUALITY • Nichrome coil element for quick heat • Powder coat paint process eliminates sharp metal edges EASY Wall can designed for ease of installation CONVENIENCE Dual fans behind single grill for quick response for larger areas General Information: The Com-Pak Twin Plus is the ideal choice f
◆ 16 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.com NOTE: Manufacturer recommends installing heater assembly after walls are finished. Heater must be cleaned every six months minimum. Technical Information: Model may be ordered with or without built-in thermostat. For optimum comfort a Cadet electronic thermostat may be used (check amperage rating). Single pole and double pole field mount thermostat kits available. Fan heaters and thermostats work best when installed on an inside wall.
The Com-Pak Bath ◆ 17 The premier choice for today’s bathrooms SAFETY Thermal Safeguard - High temperature manual reset: turns off heater if normal operating temperatures are exceeded QUALITY • Durable steel tube and plate constructed heating element - painted to resist rusting • Powder coat paint process eliminates sharp metal edges COMFORT • Ideal for instant warmth in bathrooms • Advanced built-in controls - Thermostat: range 45˚F-85˚F: with disabled (no heat) position - 60 minute timer overrides t
◆ 18 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.com Technical Information: All heaters include a built-in single pole thermostat and 60-minute timer. The Com-Pak Bath Heater is not to be used with a wall thermostat. The multi-volt option must be configured for the correct voltage before installing the heater. The multi-watt option must be configured for the desired wattage before installing the heater. UL requires heater to be placed a minimum distance of 6” from adjacent surfaces and 4.
The Perfectoe ◆ 19 The ideal choice for under cabinets SAFETY Thermal Safeguard - High temperature manual reset: turns off heater if normal operating temperatures are exceeded QUALITY • Commercial grade steel element • Powder coat paint process eliminates sharp metal edges CONVENIENCE Ideal for areas with limited wall space such as under cabinets or stairwells EASY • Wall can designed for ease of installation • Separate grill for easy installation and service General Information: The Perfectoe heate
◆ 20 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.com Technical Information: A thermostat is required. For optimum comfort use a Cadet electronic thermostat. Thermostats work best when installed on an inside wall. Single pole or double pole integral field mount thermostat kits are also available. UL requires heater to be placed a minimum distance of 6” from any inside corner or adjacent surfaces.
The SL Series ◆ 21 The ideal choice for larger areas with limited wall space SAFETY Thermal Safeguard - High temperature manual reset: turns off heater if normal operating temperatures are exceeded QUALITY Powder coat paint process eliminates sharp metal edges COMFORT • Grill design provides dual heat distribution • Unique fan reduces air turbulence for quiet heat delivery CONVENIENCE Built-in double pole thermostat with temperature range of 40°F to 85°F General Information: The SL Series is a high
◆ 22 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.com Technical Information: All models come with a built-in double pole thermostat. Fan heaters work best when installed on an inside wall. UL requires heater to be placed a minimum distance of 6” from adjacent surfaces and 6” from the floor. Manufacturer recommends installation 12” from all surfaces. A 3’ minimum clearance is required for furniture or other objects placed directly in front of heater.
The NLW Series ◆ 23 The premier choice for larger areas SAFETY Thermal Safeguard - High temperature manual reset: turns off heater if normal operating temperatures are exceeded QUALITY Powder coat paint process eliminates sharp metal edges COMFORT • Grill design provides even air distribution • Fan runs independently to circulate air in the summer • Oversized fan provides quiet operation CONVENIENCE Built-in double pole thermostat with temperature range of 40°F to 85°F General Information: The NLW S
◆ 24 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.com Technical Information: All models come with a built-in double pole thermostat. Fan heaters work best when installed on an inside wall. UL requires heater to be placed a minimum distance of 6” from adjacent surfaces and 6” from the floor. Manufacturer recommends installation 12” from all surfaces. A 3’ minimum clearance is required for furniture or other objects placed directly in front of heater.
◆ The RBF Series 25 SAFETY Primary and Secondary Thermal Safeguards - Robust, heavy duty high temperature manual power reset - Over temperature one-time thermal fuse QUALITY • Nichrome coil element for quick heat • Stainless steel grill with frame CONVENIENCE Built-in on/off switch General Information: The RBF101 is a compact bathroom fan heater that features a convenient on/off rocker switch control and a fan forced interior from our most popular heater The Com-Pak Plus.
◆ 26 EBHN Hydronic PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.com The ideal choice for bedrooms and nurseries roved! Imp SAFETY Lowest surface temperatures available QUALITY EN SEV General Information: Introducing the new EBHN Hydronic Baseboard with the lowest surface temperatures available and even better reliability and product life! Cadet’s premier hydronic baseboard line is recommended for nurseries and bedrooms, and for people with severe allergies.
The Cadet Electric Baseboard ◆ 27 The practical choice for bedrooms SAFETY Oversized high temperature limit switch with full length capillary sensor tube QUALITY • Durable steel sheathed element with a limited lifetime warranty • Rugged steel construction • White or almond powder coat paint for a durable finish EASY • Easy installation with pre-punched case at 1” intervals • Thermostats can mount on either end General Information: The electric baseboard heater is the number one choice for low cost in
◆ 28 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.com UPC Code UPC Code WATTS Model# Description 240V 208V AMPS White Part# Almond Part# 027418 05530 9 027418 05520 0 2F500-1 30" Baseboard 120V 500 240V 208V 120V 4.17 Wt./Lbs 6 027418 05532 3 027418 05522 4 3F750-1 36" Baseboard 750 6.25 7 027418 05534 7 027418 05524 8 4F1000-1 48" Baseboard 1000 8.33 9 027418 05536 1 027418 05526 2 6F1500-1 72" Baseboard 1500 12.
The Hot One ◆ ® 29 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.
◆ 30 The CEH Industrial unit heater SAFETY Thermal Safeguard - High temperature manual reset: turns off heater if normal operating temperatures are exceeded QUALITY • High mass, tubular element for long life • Rugged die formed construction for durability COMFORT • Fan delay eliminates cold draft on startup and disperses residual heat on shutdown CONVENIENCE • Wire single or three phase to suit the application • Mounts vertically or horizontally General Information: Calculate the heat loss of the area
PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.com Ordering Information: Model CEH005-P (1 Phase) is designed to use a C600M, C600S or a CEKTB2 thermostat. If you add the jumpers, as shown on the heater wiring diagram (supplied with instructions and in wiring compartment) you can use a Single Pole 22 amp wall stat or a CEKTB1 thermostat. USE ONLY C600M, C600S, OR A CEKTB2 FOR 3 PHASE hookup on this model. Approximate air throw is 12’. The CEH is recommended for elevations under 7500 feet.
◆ 32 The Cadet Garage/Utility Heater Great for garages and shops - CGH402 SAFETY Thermal Safeguard - High temperature manual reset: turns off heater if normal operating temperatures are exceeded QUALITY Finned steel tubular heating element CONVENIENCE • Open airflow design reduces debris build up • Built-in single pole thermostat with mechanical “OFF” position • Portable, great for garages and workshops • 6 foot cord with polarized plug for 240V use EASY Bracket for floor, wall, or ceiling mount Tech
The Cadet Utility Unit Heater Great for garages and shops - CGH562 ◆ 33 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.
◆ 34 Electronic Thermostats Save Energy, Improve Comfort Electronic thermostats are an easy way to reduce energy consumption and improve comfort with zonal heat.
◆ The TH106 35 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.com Electronic Programmable Thermostat FEATURES AND BENEFITS • Unsurpassed digital temperature sensing provides unbeatable accuracy of 0.15˚C / 0.
◆ 36 The TH110 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.com Electronic Programmable Thermostat FEATURES AND BENEFITS • Advanced temperature control ensures comfort by minimizing temperature swings to ±0.5˚C / 0.
The TH114 ◆ 37 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.com Electronic Non-Programmable Thermostat FEATURES AND BENEFITS • Advanced electronic temperature control in a non-programmable thermostat minimizes temperature swings to ±0.5˚C / 0.
◆ 38 The TH401 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.com Electronic Non-Programmable Thermostat FEATURES AND BENEFITS • Unsurpassed digital temperature sensing provides unbeatable accuracy of 0.15°C / 0.
The V8-BB-7S ◆ 39 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.com Electronic Programmable Occupancy Sensing Thermostat FEATURES AND BENEFITS • Occupancy detection allows maximum energy savings! • Short Vacancy: Reduce temperature set point by a few degrees minutes after room becomes unoccupied, and instantly start saving energy. Once room occupancy is detected again, set point is restored to maintain desired comfort level.
◆ 40 The Smart-Base Electronic Programmable Baseboard Thermostat PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.
T4398 Series ◆ 41 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.
◆ 42 T410 Series PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.
M600 Series ◆ 43 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.
◆ 44 Bimetal and Specialty Thermostats PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.com C600 Series: Specialty Line Voltage Bimetal Thermostat General Information: This line of thermostats meet comfort needs, while optimizing economy and energy efficiency. The C611 anticipated thermostat controls temperature equal to or better than a typical low voltage thermostat. The increased bimetal thickness in the C600 Series prevents damage and gives improved thermal differential performance.
Adapters ◆ 45 PHONE 360.693.2505 FAX 360.694.8668 WEB www.cadetco.com Cost-effective alternatives Metal Adapter Plates FEATURES AND BENEFITS • Easily replace outdated electric wall heaters • Cost-effective • Powder coated metal • Can be painted to match room décor • Time-saving / no wall repair CAMW CTAMW SAMW General Information: A cost-effective alternative to remodeling. Adapter plates allow replacement of older or obsolete electric wall heaters without the added expense of remodeling.
◆ 46 Cadet Manufacturing Warranty Information Warranty Information Maintenance: For more effective and safer operation and to prolong the life of the heater, read the Owner’s Guide and follow the maintenance instructions included with each heater. Failure to properly maintain the heater will void any warranty and may cause the heater to function improperly. Warranties are non transferable and apply to original consumer only. Warranty terms are set out below.
EDI Electronic Data Interchange & Conditions of Sale EDI (Electronic Data Interchange) Information Cadet Manufacturing Co. utilizes EDI to exchange information, making it easier to do business. Information exchanged includes incoming Purchase Orders, Invoices, Advance Ship Notices and Text Messages. EDI Standards Cadet supports ANSI X.
Safe, Quality Solutions Cadet is committed to safe, quality heating solutions. Every heater is factory tested prior to being shipped and comes equipped with industry leading safety components to ensure safety and peace of mind. Cadet employs sustainable business practices throughout our facility and product life cycle. Cadet Manufacturing 2500 W. Fourth Plain Blvd Vancouver, WA 98660 Phone: 360-693-2505 Fax: 360-694-8668 www.cadetco.com Printed in U.S.A. 10/11 #070508 ©2011 Cadet Manufacturing Co.