Installation Guide

ON DIP
1234
Please note: The TH106 comes factory set in baseboard
mode (even though the Honeywell Owners Guide
incorrectly reects a factory setting of fan mode). If using
the TH106 to control a fan-forced heater, you must change
the setting for switch 3.
To change the setting from baseboard to fan
heater: The conguration switches are on the back of the
thermostat cover. Change factory setting for switch 3 to the
right, or ‘ON’ position (5 minute cycle length). See page 2 of
your thermostat Owners Guide, Section 3 Conguration,
for more detailed information on switch settings.
Instructions are also available on our website at cadetheat.com
IMPORTANT INSTRUCTIONS
FOR FAN-FORCED HEATER USE
switch
3
15 second
cycles
Baseboard
5 minute
cycles Fan
Heater
LEFT for
Baseboards
RIGHT for
Fan Heaters
Rev 07/15 7 2 0 0 1 8
Switch 3 Setting
conguration
switches