Installation Manual

1. Verify that the LTF-240 receptacle conguration (See Figure 1)
matches the appliance plug.
2. LTF must be installed at end of baseboard that carries the
incoming power supply.
3. Detach the baseboard junction box cover by removing the
retaining screw at the end where the load transfer switch will
be installed. Save the retaining screw for use in step 8.
4. Connect the 240 VAC incoming power supply wires to the
leads marked “line” on the switch (See Figure 2).
5. Connect the heater element leads to the LTF leads marked
“heater” (See Figure 2).
6. Connect the three ground wires together.
7. Check that no bare wire is exposed and that all wire
connections are tight.
8. CAUTION: Be certain the ground wires do not come in contact
with the terminal connections of the switch or outlet. Attach the
LTF plate to the heater using the screw that was set aside.
9. Turn on the power to the heater.
INSTALLATION INSTRUCTIONS
Figure 1
HEATER OUTLET
NOTES
A single pole Cadet brand BTF1 thermostat must be
installed at the other end of the baseboard.
• NOT intended for use with wall thermostat
• Will not support double pole thermostat
ROCKER
SWITCH
LINE
LINE
HEATER
HEATER
SWITCH
RECEPTACLE
OUTLET
NEMA
620R
GROUND
LTF-240
20 AMP, 240V, 60 HZ
USE ONLY ON 20 AMP, BRANCH CIRCUIT
FOR USE WITH MODELS F, M, R
UL LISTED BASEBOARD ACCESSORY 631J
LINE
LINE
GROUND
HEATER
HEATER
SWITCH
LTF-240
20 AMP, 240V, 60 HZ
USE ONLY ON 20 AMP, BRANCH CIRCUIT
FOR USE WITH MODEL F
UL LISTED BASEBOARD ACCESSORY 631J
RECEPTACLE
Figure 2
WARRANTY
©2016 Cadet Printed in U.S.A. 11/16 #720031
LIMITED ONE-YEAR WARRANTY: Cadet will repair or replace any Cadet
product, including thermostats, found to be defective within one year after the
date of purchase.
These warranties do not apply:
1. Damage occurs to the product through improper installation or incorrect
supply voltage;
2. Damage occurs to the product through improper maintenance, misuse,
abuse, accident, or alteration;
3. The use of unauthorized accessories or unauthorized components constitutes
an alteration and voids all warranties. Refer to Cadet website or call customer
service at 855.CADET.US for list of authorized accessories and components.
4. CADET’S WARRANTY IS LIMITED TO REPAIR OR REPLACEMENT.
5. IN THE EVENT CADET ELECTS TO REPLACE ANY PART OF YOUR CA-
DET PRODUCT, THE REPLACEMENT PARTS ARE SUBJECT TO THE
SAME WARRANTIES AS THE PRODUCT. THE INSTALLATION OF RE-
PLACEMENT PARTS DOES NOT MODIFY OR EXTEND THE UNDERLYING
WARRANTIES. REPLACEMENT OR REPAIR OF ANY CADET PRODUCT
OR PART DOES NOT CREATE ANY NEW WARRANTIES.
If you believe your Cadet product is defective, please contact Cadet
during the warranty period, for instructions on how to have the repair or
replacement processed.
Parts and Service
Visit cadetheat.com/parts-service for information on where to obtain parts
and service.
Reduce-Reuse-Recycle
This product is made primarily of recyclable materials. You can
reduce your carbon footprint by recycling this product at the end
of its useful life. Contact your local recycling support center for
further recycling instructions.
For more effective and safer operation and to prolong the life of the heater, read the Owner’s Guide and follow the instructions. Failure to
properly maintain the heater will void any warranty and may cause the heater to function improperly.
OPERATING INSTRUCTIONS
Use the rocker switch to direct power to the baseboard heater OR the 240 volt outlet (See Figure 1).