Installation Guide

CONSULT LOCAL ELECTRICAL CODES TO DETERMINE WHAT WORK MUST BE PERFORMED BY QUALIFIED ELECTRICAL SERVICE PERSONNEL
Gurgling noise
Heater not
working
Liquid found in
or around unit
Room does not
heat quickly
Heater will
not shut off
1. Unit may not be level
2. Unit may have developed a leak
1. Heater does not have proper
voltage to function correctly
2. Unit wired incorrectly
1. Heat transfer fluid may be
escaping from element
1. Unit is slow to heat
2. Unit wired incorrectly
1. Heat loss from room is greater
than heater capacity
2.
Defective thermostat
3. Thermostat
wired incorrectly
to heater
Symptom Problem Solution
427&/)5,226-1+,%46
# $
Maintenance: For more effective and safer operation and to prolong
the life of the heater, read the Owner’s Guide and follow the maintenance
instructions included with each heater. Failure to properly maintain the
heater will void any warranty and may cause the heater to function
improperly. Warranties are non transferable and apply to original
consumer only. Warranty terms are set out below.
LIM
ITED ONE-YEAR WARRANTY: Cadet Manufacturing Co. will repair
or replace any Cadet product, including thermostats, found to be
defective or malfunctioning from first date of purchase through the
first year.
LIMITED SEVEN-YEAR WARRANTY: Cadet Manufacturing Co. will
repair or replace any Cadet/Softheat baseboard (EBHN) found to be
defective or malfunctioning from first date of purchase through the
seventh year.
THESE WARRANTIES DO NOT APPLY:
1. Damage occurs to the product through improper installation or
incorrect supply voltage;
2. Damage occurs to the product through improper maintenance,
misuse, abuse, accident, or alteration;
3. The product is serviced by anyone other than Cadet;
4. If the date of manufacture of the product cannot be determined;
5. If the product is damaged during shipping through no fault
of
Cadet.
6. CADET’S WARRANTY IS LIMITED TO REPAIR OR REPLACEMENT
AS SET OUT HEREIN. CADET SHALL NOT BE LIABLE FOR
DAMAGES SUCH AS PROPERTY DAMAGE OR FOR CONSEQUEN-
TIAL DAMAGES AND/OR INCIDENTAL EXPENSES RESULTING
FROM BREACH OF THESE WRITTEN WARRANTIES OR ANY
EXPRESS OR IMPLIED WARRANTY.
7. I
N THE EVENT CADET ELECTS TO REPLACE ANY PART OF YOUR
CADET PRODUCT, THE REPLACEMENT PARTS ARE SUBJECT TO THE
SAME WARRA
NTIES A
S THE PRODUCT. THE INSTALLATION OF
REPLACEMENT PARTS DOES NOT MODIFY OR EXTEND THE UNDER-
LYING WARRANTIES. REPLACEMENT OR REPAIR OF ANY CADET
PRODUCT OR PART DOES NOT CREATE ANY NEW WARRANTIES.
8. These warranties give you specific legal rights, and you may also
have other rights which vary from state to state. Cadet neither
assumes, nor authorizes anyone to assume for it, any other oblig-
ation o
r liability in connection with its products other than as set
out herein.
If you believe your Cadet product is defective, please, contact
Cadet Manufacturing Co. at 360-693-2505, during the warranty period,
for instructions on how to have the repair or replacement
processed. Warranty claims made after the warranty period has
expired will be denied. Products returned without authorization
will be refused.
Parts and Services
Visit http://support.cadetco.com for information on where to obtain
parts and service.
Reduce-Reuse-Recycle
This product is made primarily of recyclable materials. You
can reduce your carbon footprint by recycling this product
at the end of its useful life. Contact your local recycling
support
center for further recycling instructions.
©2011 Cadet Manufacturing Co. Printed in U.S.A. 12/11 #706955
* What to do if the solution in your Softheat Baseboard should leak out:
The solution in your Softheat Baseboard is a non-toxic thermal fluid (Material Safety Data Sheet available upon request). This solution is
non-toxic if ingested, and there is no immediate health concern with air quality following a spill. Take adequate precautions to keep
people and animals away from leakage. Non-porous rubber g
loves and eye protection should be worn during clean-up if exposure and
contact lasts longer than two hours.
Soak up spill with an absorbent material such as paper towels. Once excess liquid or residue has been absorbed, a non-oxidizing cleanser
such
as an orange citrus cleaner can be used to remove any remaining dried residue (first test a hidden section of flooring for colorfastness).
Scrub spill a
rea, then use absorbent material to remove any remaining cleanser. Several applications of the cleanser may be required,
depending on size and amount of spill.
1. Check to be sure unit is level. If gurgling doesn't stop within 30 minutes, unit needs to be replaced.
2. Replace element or heater.
1. Circuit breaker could be positioned incorrectly. Relocate breaker. Check voltage at the heater
between su
pply wires and make sure it matches required heater voltage.
2. Using Owners Guide, verify wires are connected properly and securely with appropriate wire nuts.
If the unit is still not operating, further testing should be done with ohmmeter. Consult an electrician.
1. Immediately discontinue use.* Replace element or heater (elements are not repairable).
1. No solution necessary - typical initial warm
-up takes 30-60 minutes.
2.
Check voltage at the heater between supply wires and make sure it matches required heater voltage.
1. Close doors and windows. Provide additional insulation, install a higher-wattage heater or multiple
heaters, if necessary.
2. Adjust thermostat to its lowest setting. If heater continues to run (allow two minutes for the
thermostat to respond), replace thermostat.
3. Refer to
thermostat documentation and correct wiring.
5
TERMOSTATO
Se requiere un termostato. Se recomienda un termostato mural Cadet
para un óptimo rendimiento, o bien puede optar por la comodidad de
un juego de termostato EBKN DPST incorporado. En las instrucciones
incluidas con el termostato encontrará información sobre el cableado
del mismo. Si ha de instalar un termostato, consulte la sección que
aparece más adelante en esta guía titulada “Paso 3: Termost
ato”
antes de instalar el zócalo.
UBICACIÓN
Para mejores resultados, instale el calentador de zócalo Softheat bajo
una ventana, junto a una pared exterior o lo más cerca posible de una
puerta que dé al exterior. Siga estas instrucciones para seleccionar un
área de instalación ideal:
ANTES DE PROCEDER CON LAS INSTRUCCIONES DE INSTALACIÓN, DEBE CONSIDERAR
DIVERSOS FACTORES QUE SON FUNDAMENTALES PARA LA INSTALACIÓN.
CABLEADO
La conexión estándar de los cables se hace en el lado izquierdo
del calentador de calo. Determine en qué lado del calo hará
las conexiones ubicando los cables de suministro. Los calentadores
se pueden comprar como pedido especial para una configuracn
con conexión de alambres al lado derecho. Debe ubicar los cables
antes de montar el calentador. Consulte la sección tituladaPaso
3:
Termostato antes de cablear el zócalo si es que instalará un
termostato mural.
VOLTAJE (TODOS LOS MODELOS)
Es extremadamente importante verificar que los alambres de
suministro ectrico sean del mismo voltaje que el calentador (es
decir, un calentador de 120 voltios con un suministro de enera
del mismo voltaje, y un calentador de 240 voltios con un suministro
de enera de ese mismo valor). Si va a reemplazar un calentador
existente, revise las etiquetas del calentador antiguo y sustitúyalo
por otro del mismo voltaje. Si se conecta un calentador de 240
voltios a un suministro de energía de 120 voltios, se reduci
drásticamente el rendimiento del calentador. Si se conecta un
calentador de 120 voltios a un suministro de enera de 240 voltios,
se destruirá el calentador.
NIVEL
El calentador de zócalo Softheat debe estar correctamente nivelado
cuando se instale, para que la cámara de calentamiento funcione
debidamente.
ACERCA DEL CALO ELÉCTRICO SOFTHEAT DE CADET: El zócalo ectrico Softheat de Cadet está diseñado para brindar calor zonal a una
habitacn usando convección a fin de hacer circular el aire caliente en forma natural. La seguridad es la principal prioridad de Cadet. Todos
los zóca
los Softheat incluyen un interruptor límite de alta temperatura y gran tamaño con restablecimiento automático que apaga el calentador
cuando se detectan temperaturas de operación excesivas. Para una operación eficaz y segura, y para prolongar la vida útil del calentador, lea
todas las instrucciones e información de seguridad y acate las instrucciones de mantenimiento de la presente Guía del propietario.
15647''-21)53%4%/%-156%/%'->1
NO INSTALE EL ZÓCALO DEBAJO
DE UN TOMACORRIENTE ELÉCTRICO.
NO INSTALE NINGÚN ZÓCALO EN FORMA VERTICAL.
MONTE EL ZÓCALO ÚNICAMENTE
EN POSICIÓN HORIZONTAL
La unión donde confluyen la pared y el piso dets de los
calentadores se debe calafatear para evitar el ingreso de polvo
a la habitación.
El calentador se debe instalar a ras de la superficie de la muralla.
Retire toda obstruccn entre la parte trasera de la unidad y la
superficie de la pared.
El calentador de zócalo puede instalarse directamente en la
superficie de cualquier tipo de piso, incluyendo alfombra.
Mantenga por lo menos un espaciado mínimo de 12 pulgadas
respecto de los objetos que cuelguen por encima (por ejemplo,
cortinas).
8