Installation Guide

INSTALLATION INSTRUCTIONS (continued)
Correct240VoltConguration Correct120VoltConguration
CB132T Multi-Watt
CB103T Multi-Volt
DESIRED WATTAGE:
DO NOT DISCONNECT THE YELLOW CONNECTOR FROM TERMINAL "A"
Factory set at 1300 Watts
1300/975
800/600
500/375
WIRE CONFIGURATION240/208V
No change
Disconnect and cut BLUE connector from terminal
C. Wrap loose wire end with electrical tape. Move
YELLOW connector at terminal B to the C terminal.
Cut wire with BLUE connector at terminal C. Wrap
loose wire end with electrical tape.
PN070350
A
B
C
White Wire
Black Wire
Blue Wire
Red Wire
White Wire
Black Wire
Blue Wire
Red Wire
Heater must be connected to a GFCI protected branch circuit.
Refer to wiring diagrams, and Figure 6 for desired voltage. Before
installing the heater, it is extremely important you verify the
heaterisconguredforthecorrectsupplyvoltage.TheMulti-Volt
Com-PakBathroomHeaterisconguredfor240voltoperationby
default.For120voltinstallationyoumustreconguretheheater
wiring.Installingtheheaterwithoutconguringforthecorrect
voltage will destroy the heater and void your warranty.
How to determine the supply voltage:
If replacing an existing heater, check the labels of the old heater
and replace using same voltage. For new construction, heater
wiresmustbeconguredtothesamevoltageasthesupplywires.
Ifyouneedassistance,consultaqualiedelectrician.
Select Proper Heater Voltage
STEP 2
For 240 volt conguration:
TheMulti-VoltCom-PakBathroomHeaterisconguredfor240
volt operation by default. Important! The red wire and its terminal
endarenotconnectedinthisconguration.
For 120 volt Conguration:
Tocongureheaterfor120volt,disconnectthebluewirefrom
terminal D and connect it to terminal A. Then connect the loose
red wire to terminal D.
____________
Part Two
____________
After you have followed all instructions in Part One you are ready to install the heater assembly.
Install Heater Assembly
STEP 3
Install Grill
STEP 4
Secure grill with the screws provided. Slide thermostat knob onto
right control shaft extending through the grill and the timer knob
onto the left shaft. Turn power on at the main disconnect panel.
Turn heater assembly upside down (element down with motor facing up). Connect the supply wires to the heater wires with wire con-
nectors (not included). (See Figures 7 and 8). Now rotate the heater so the element and the fan are facing up. The element should be
at the top.
Insert the bottom edge of the heater assembly into the half round slots in the bottom lip of the wall can (See Figure 9). [IMPORTANT:
Push wires into bottom of wall can during insertion. Be sure that supply wires are not caught between motor and wall can.] Attach
assembly at top with screw provided.
Figure 5
Figure 7 Multi-Volt
(Model CB103 shown)
Figure 8 Multi-Watt
(Model CB132 shown)
Figure 9
How do I congure the Multi-Volt model CB103? How do I congure the Multi-Watt model CB132?
Determine Supply Voltage
STEP 1
Multi-Watt Element Wiring Conguration
STEP 1
Heater must be connected to a GFCI protected branch circuit.
Use the table in Figure 5 to select the correct wattage required,
and the element terminals to be used.
Figure 6
Note: Warranty is void if any material is sprayed on the element
or blower. Use a paint mask to cover any exposed areas of the
heater if walls are to be textured or painted.
Proceed to STEP 3.
Proceed to STEP 3.
How do I insert the heater assembly into the wall can?
Page 4
A
B
C
D
A
B
C
D