Installation Guide

BTF WIRING INSTRUCTIONS CONCLUSION - PART 3
STEP 6
Carefully tuck all wires into wiring compartment
and attach the thermostat to the baseboard heater.

A. Connect the
r
ed
thermostat
wire labeled L2 to the
b
lack
thermostat wire labeled OFF
as shown.
Model BTF2 120 Volt Application
B. Connect the neutral supply
wire to one of the heater wires.
C. Connect the supply hot
wire to the remaining
r
ed
thermostat wire.
D. Connect the remaining
b
lack
thermostat
wire to the remaining heater wire.
PROCEED TO PART 3
RED
GROUND
SCREW
GROUND
SCREW
GROUND
SCREW
FIELD WIRING
FIELD WIRING
GROUND
SCREW
GROUND
SCREW
FIELD
WIRING
NOT
PROVIDED
FIELD WIRING
NOT PROVIDED
FIELD WIRING
NOT PROVIDED
GROUND
SCREW
FIELD WIRING
GROUND
SCREW
FIELD WIRING
NOT PROVIDED
BTF2
1. Disconnect one factory connector on each baseboard.
2. Connect one supply wire to each
r
ed
thermostat wire.
3. Connect one
b
lack
thermostat wire to one wire from each heater.
4. Connect remaining
b
lack
thermostat wire to the remaining wire from each heater.
5. Connect supply ground wire to both ground screws.
IMPORTANT: Wires shown in illustration are for reference only. All electrical
work and materials must comply with the National Electric Code (NEC) and all
state and local codes.
NOTE: Field wiring is not provided.
BTF1
1. Disconnect one factory connector on each baseboard.
2. Connect one supply l
ead to the
r
ed
thermostat wire.
3. Connect
b
lack
thermostat wire to one wire on each heater.
4. Connect remaining wire from each heater to the remaining supply lead.
5. Connect supply ground wire to both ground screws.
IMPORTANT: Wires shown in illustration are for reference only. All electrical
work and materials must comply with the National Electric Code (NEC) and
all state and local codes.
NOTE: Field wiring is not provided.
More than one baseboard
heater can be wired in parallel on same circuit (be sure to check national and local codes for safety requirements).
Additional wire is required. Important: When wiring multiple heaters to one thermostat, the baseboards must be in the same room.
Maximum amperage rating: 22 amps.
MULTIPLE HEATER WIRING - OPTIONAL
