Installation Guide

GROUND
SCREW
GROUND
SCREW
Model BTF2 240/208 Volt Application
A. Connect the black thermostat wires to the
loose heater wires.
B. Connect the hot supply wires to the red
thermostat wires.
PROCEED TO PART 3
STEP 1
Turn the electrical power off at
the circuit breaker or fuse box.
STEP 2
Remove the junction box cover
at the end of the baseboard
you wish to wire.
STEP 4
Disconnect one factory connector
on the side you have open,
leaving two loose heater wires.
PART 2
BTF WIRING INSTRUCTIONS - PART 1
Model BTF1 - 120 Volt Application
A. Connect the hot supply wire to the red
thermostat wire.
B. Connect the black
thermostat wire to one
of the heater wires.
C. Connect the neutral supply wire to the
remaining heater wire.
PROCEED TO PART 3
A. Connect a hot supply wire to the red
thermostat wire.
Model BTF1 240/208 Volt Application
B. Connect the black thermostat wire to one
of the heater wires.
C. Connect the remaining hot supply wire
to the remaining heater wire.
PROCEED TO PART 3

STEP 3
Connect the supply grounding
wire to the green grounding
screw provided.
GROUND
SCREW
GROUND
SUPPLY
GROUND
SCREW
GROUND
SCREW
GROUND
SCREW
GROUND
SCREW
GROUND
SCREW
GROUND
SCREW
GROUND
SCREW
STEP 5: REFER TO THE INSTRUCTIONS BELOW THAT CORRESPOND TO YOUR THERMOSTAT APPLICATION.