Specifications
- 62 -
AS/CA S002:2010 COPYRIGHT
OCTOBER 2010
APPENDIX
C AUTOMATIC STUTTER DIAL TONE DETECTION
C1 General
C.1.1 Line seizure for stutter dial tone detection
CE may automatically seize the line to detect the presence or
absence of stutter dial tone for the purposes of message wait
indication. Where CE performs this function it shall do so in
accordance with the requirements of this Appendix.
C.1.2 Conditions for automatic stutter dial tone detection
CE shall perform automatic stutter dial tone detection under one or
more of the following conditions:
(a) Perform periodic stutter dial tone detection in accordance
with Clause C3.
(b) Go ON-LINE to test for stutter dial tone no more than once
after a customer completes a call (outgoing or incoming), and
commence the check no earlier than 15 s after the PSTN line
has been released.
(c) Provided the visual message indicator is currently inactive, the
CE may go ON-LINE once to test for stutter dial tone after an
unanswered call not less than 5 min after the cessation of the
incoming ringing signal.
C2 Tone detection
C.2.1 Maximum duration
When performing an automatic stutter dial tone detection the CE
shall seize the line for a maximum duration of 4.0 s to test for stutter
dial tone.
Note: PSTN service tone characteristics are described in Appendix A.
C.2.2 Parallel connected CE
C.2.2.1 The CE shall incorporate a means of detecting line seizure by
parallel connected CE such that only a single line seizure occurs
when a stutter dial tone test is performed.
C.2.2.2 The CE should incorporate a means of detecting line seizure by
parallel connected CE so that only a single CE automatically seizes
the line to test for stutter dial tone. When initially configured for
automatic stutter dial tone testing, multiple CE may seize the line for
the first periodic detection interval but should not do so during
subsequent detection intervals.