Specifications

- 21 -
AS/CA S002:2010 COPYRIGHT
OCTOBER 2010
2.5 s. The answering tone should be in the range from –7 dBm
to –13 dBm; or
(c) a post-answer tone dissimilar from a PSTN dial tone, PSTN ring
tone, busy tone, or NU tone, as described in Appendix A.
Compliance with Clause 5.3.5.3.2 should be checked by using the
method described in Clause 6.7.9 as appropriate.
5.3.5.4 Commencement of dialling
5.3.5.4.1
CE which is not able to detect dial tone shall not commence dialling
earlier than 2.7 seconds after the seizure state as specified in
Clause 5.5.1.4 has been established.
Note: A time delay not exceeding 6 seconds is recommended.
5.3.5.4.2 CE which is able to detect dial tone may commence dialling after
the presence of dial tone has been detected.
Compliance with Clause 5.3.5.4 should be checked by operation
and inspection.
5.3.5.5 Automatically repeated call attempts
5.3.5.5.1
CE shall provide a minimum OFF-LINE period of 5 s following the
termination of an unsuccessful call attempt before automatically
initiating a subsequent call attempt in a repeated call attempt
sequence.
5.3.5.5.2 CE shall not automatically initiate more than 15 call attempts,
including the initial call, in a repeated call attempt sequence.
5.3.5.5.3 If the call attempt sequence described in Clauses 5.3.5.5.1 and
5.3.5.5.2 is unsuccessful, CE shall not automatically re-initiate the call
attempt sequence to the same number.
5.3.5.5.4 CE should provide a minimum OFF-LINE period of 5 s following the
termination of an unsuccessful call attempt sequence before
automatically initiating a new call attempt sequence to a different
number.
Note 1: The interval between repeat call attempts in most practical
applications should be set to a value considerably greater than the
minimum allowed value so as to provide an appropriate
compromise between the rate of redialling and the likelihood of the
repeat call attempt being successful, taking into account the
typical holding time for calls.
Note 2: It is highly recommended that CE which provides the automatic
repeat call function should incorporate service tone detectors
which meet the requirements of Clause 5.3.5.2, in order to improve
functionality and reduce loop holding times for unsuccessful call
attempts.
Compliance with Clause 5.3.5.5 should be checked by operation
and inspection.