Specifications

- 13 -
AS/CA S002:2010 COPYRIGHT
OCTOBER 2010
TABLE 2
Standard ten-pushbuttons keypad
arrangement and numbering
1 2 3
4 5 6
7 8 9
* 0 #
Note: The ‘*’ and ‘#’ symbols are commonly known as ‘star’ and ‘hash’
respectively.
5.1.6.4 Where letters, in addition to numerals, appear on a keypad or rotary
dial, or its surround, the Letters and numerals shall
(a) conform to the associations given in Table 3;
(b) be unambiguously associated with the relevant keys; and
(c) have a distinct difference in style between the numeric zero
and the letter ‘O’.
Note: The inclusion of a slash across numeric zero is optional.
Compliance with Clause 5.1.6 should be checked by inspection.
TABLE 3
Alphanumeric mapping
1 2 ABC
3 DEF
4 GHI 5 JKL 6 MNO
7 PQRS
8 TUV 9 WXYZ
* 0 #
Note: Inclusion of alphabetic characters on keypads/dials is optional.
5.1.7 Insulation resistance of ring-in/loop-out PSTN lines
5.1.7.1
CE in the OFF-LINE state, except as provided for in Clauses 5.1.7.2
and 5.1.7.3, shall have an insulation resistance of not less than 1 M
between
(a) the two line conductors;
(b) each line conductor and TRC terminal, if equipped; and
(c) each line conductor and PE terminals, if equipped
when tested with 250 V d.c. of each polarity, in series with a 600 k
resistance.
Compliance should be checked by measuring the DC resistance
between the line conductors and between each line conductor
and the TRC terminal and the power supply protective earth