Specifications

26 IBM Voice Over Frame Relay Perform Guide
4. You are prompted to reenter your password as a confirmation. Retype it and
press the Enter key.
3.1.2 Getting Started
Perform the steps in this section for each of the IBM 9783 units in the installation
(both local and remote units) before physical connections are made.
3.1.2.1 Assigning Unit Addresses
After you have determined the system configuration settings, completed the initial
powering procedures, and assigned passwords, you must assign unique node IDs
to each unit.
1. At the IBM 9783 terminal, press the Enter key to display the local unit prompt.
2. Each IBM 9783 unit in the system must be assigned a unique IP address
before remote communications over the composite channel can occur. Use the
UNIT ADDRESS command to assign these addresses. At the Local prompt, type
the following command:
UNIT ADDRESS < ip_address>
where ip_address is a series of four numbers, each number being one to three
digits, separated by periods. The factory default address for each IBM 9783
unit is 0.0.0.1.For example:
The unit resets after the unit address is set. This procedure requires
approximately five minutes.
3. Use the
UNIT DATE command to set the system date.
4. Use the
UNIT TIME command to set the system time.
Enter new password: *****
Enter new password: *****
Retype new password: *****
Local:tokyo>Local:PASSWORD> OK
Local:tokyo> unit address 0.0.0.20
Local:tokyo> unit date 08/12/99
Local:SYS-DATE> OK
Local:tokyo> unit time 18:15
Local:SYS-TIME> OK