en WOOD STOVE installation, use and maintenance manual aurora - sole ©2014 CADEL srl | All rights reserved – tutti i diritti riservati
Summary EN 12.4 FANS CLEANING .......................................22 12.5 GENERAL CLEANING ...............................22 1 MANUAL SIMBOLOGY......................................3 12.6 CLEANING OF PAINTED METAL PANELS .....22 2 DEAR CUSTOMER...............................................3 12.7 CLEANING OF CERAMIC PANELS ...........22 3 CAUTIONS..........................................................3 12.8 FAN REPLACEMENT ..................................22 4 WARRANTY CONDITIONS........
1 MANUAL SIMBOLOGY • The icons with the stylized figures indicates whom the subject dealt in the paragraph is addressed to (between the User and/or the Authorized Technician and/or the Specialized Stove-repairer). • WARNING symbols indicates an important note.
EN WARRANTY CONDITIONS The company guarantees the product, with the exception of elements subject to normal wear listed below, for a period of 2 (two) years from the date of purchase attested by: • a document to serve as proof of purchase (invoice and/or receipt) that shows the name of the vendor and the date on which the purchase was made; • forwarding of the completed certificate of guarantee within 8 days of purchase.
SPARE PARTS For each repair or adjustment which should be necessary, please contact the dealer where you purchased your stove or your nearest Technical Assistance Service, specifying: • Appliance model • Serial number • Type of problem Use only original spare parts which you can find at our Technical Assistance Services. 6 WARNINGS FOR THE CORRECT DISPOSAL OF THE PRODUCT 7 PACKAGING AND HANDLING 7.1 PACKAGING The owner is the sole party responsible for demolishing and disposing of the product.
EN 8 CHIMNEY FLUE 8.1 INTRODUCTION This chapter about the Chimney Flue has been drawn up in cooperation with Assocosma (www.assocosma.org) and is based on European Standards (EN 15287 - EN 13384 - EN 1856 - EN 1443 - UNI 10683:2012). It provides instructions for a good and correct execution of the chimney flue but it does not absolutely replace the current standards which the qualified manufacturer/installer should comply with.
• • • • • the adjacent room and it must be provided with a solid and condensation collection chamber under the entrance, accessible through the sealed metal gate. The inner section of the chimney flue can be round (the best one) or square and the jointed sides must have a minimum radius of 20 mm. The section dimension must be minimum Ø150 mm and maximum Ø240 mm.
.7 CHIMNEY COMPONENTS EN Fig. 4 - Chimney components LEGEND 1 2 3 4 5 6 7 8 9 10 8.8 Fig. 5 page 8 Chimney pot Fume outlet Chimney flue Termal insulation External wall Chimney union Fume pipe Heat generator Inspection door Damper EXTERNAL AIR INLET Fig. 5 - Direct air inflow 8 Fig.
LEGEND 1 2 3 4 Fig. 6 page 8-Fig. 7 page 8 Room to ventilate Adjacent room External air inlet Cleft under the door EN • The room must be endowed with an external air recycling for a good climate in your ambient. • The air inflow from outside to the inner occurs directly, through an opening on the external wall of the room (see Fig. 6 page 8); otherwise it occurs indirectly by air suction from rooms adjacent to the one to ventilate (see Fig. 7 page 8).
8.10 EXAMPLES OF CORRECT INSTALLATION EN Fig. 7 - Example 1 LEGEND 1 2 3 4 5 Fig. 8 page 10 Insulating material Reduction from Ø150 to Ø120 mm Inspection plug Minimum safety distance = 0,5 mt Damper • Chimney flue installation Ø150 mm with an enlarged drilling for pipe transit. Fig. 8 - Example 2 LEGEND 1 2 3 4 5 6 7 10 Fig.
• Old chimney flue with an inserted pipe of minimum Ø150 mm and with an external door which enables the chimney cleaning. EN Fig. 9 - Example 3 LEGEND 1 2 3 4 Fig. 10 page 11 Insulating material Inspection plug Minimum safety distance = 0,5 mt Damper • External chimney flue entirely made up of insulated stainless steel pipes, i.e. with double wall of minimum Ø150 mm: all must be firmly attached to the wall. For chimney against wind effects please (see Fig. 4 page 7).
EN Fig. 10 - Wood positioning To know the lenght of wood log to use, check the dimensions of stove combustion chamber. It is advisable to place the wood in horizontal position (see Fig. 11 page 12) and adjust the air flow with the aid of the register. To ignite proper ignitier products can be used.
10 INSTALLATION 10.1 INTRODUCTION EN • The assembly position dipends on on environment, exhaust, chimney flue. • Check with local authorities if there are any restrictive regulations which regard the combustible air inlet, room ventilation, fume exhaust system together with chimney flue and chimney pot.
10.2 OVERALL DIMENSIONS (AURORA MODEL) EN Fig. 11 - Overall dimensions LEGEND 1 2 3 4 5 6 7 8 14 Fig. 12 page 14 70 cm 109,5 cm 53 cm 35 cm 12 cm 35 cm 92 cm Exhaust fumes d.
10.3 OVERALL DIMENSIONS (SOLE MODEL) EN Fig. 12 - Overall dimensions LEGEND 1 2 3 4 5 6 7 8 AURORA - SOLE Fig. 13 page 15 60,3 cm 121 cm 50 cm 30,1 cm 12 cm 30,1 cm 85 cm Exhaust fumes d.
10.4 GENERAL INSTALLATION EN Fig. 13 - General installation LEGEND 1 2 3 4 5 6 Fig. 14 page 16 Stove Minimum lateral distance = 500 mm Minimum rear distance = 500 mm Minimum front distance = 1000 mm 300 mm 500 mm • Please check that the floor has an adequate load capacity. If the existing one does not satisfy this requirement, appropriate measure should be provided (for example a plate for distributing the load).
10.5 MAJOLICAS ASSEMBLY (AURORA MODEL) EN Fig.
10.6 MAJOLICAS ASSEMBLY (AURORA SOLE) EN Fig. 15 - Sole majolicas assembly 10.7 ELECTRIC CONNECTION Some wood stove models are endowed with a forced ventilation system, so they need an electric connection. Warning: the appliance must be installed by an authorized technician! • The electric connection occurs through a cable with plug put in an electric socket which is able to support charge and tension specific of every model, as described in the technical datas table (see FEATURES page 26).
• Please further assure you that your network is endowed with an efficient earth connection: if it does not exist or if it is not efficient, please endow you with one in compliance with the law. • Do not use extension cables. • If the feeder cable is damaged, it must be replaced by an authorized technician. • When the stove is not going to be used for a long period of time, it advisable to remove the plug from the socket on the wall. 11 USE 11.
Do not open and close the fire door violently: the glass can brake! EN Open the fire door with naked flames can be dangerous for user and/or home. During operation some external parts can reach high temperatures. During refilling fases use proper protection gloves given as equipment. • It is advisable to refill the stove only when on the firebox are only embers.
11.7 ADVERSE WEATHER CONDITIONS When the external temperatures are severe and/or there are adverse weather conditions (strong wind), the chimney is subjected to a lack in draught thus impeding a correct fume expulsion. • Fill the heart with few wood logs and keep air register valves opened completely. 11.8 CREOSOTE DANGER The use of humid and/or bad quality wood (for example resinous wood) cause creation of creosote along the chimney flue obstructing fume passages.
EN 12.3 FUME PIPES ANNUAL CLEANING Clean once a year from soot with brushes. The cleaning operation must be executed by a specialized stove-repairer who will provide for the cleaning of fume pipe, chimney flue and chimney pot. He will also check their eficiency and will release a written declaration of the safety of the appliance. This operation must be executed at least once a year. 12.
Use exclusively original spare parts. 12.10 EN GLASS CLEANING The glass-ceramic of the fire door is able to stand till 700°C but not to thermal shocks. The probable cleaning with usual sale product for glass cleaning must be effected at cool glass in order to avoid explosions. 12.11 OVEN CLEANING Some models are endowed with a oven for the foods cooking. Clean the oven inner after every cooking by using a soft cloth with hot water or appropriate products.
EN 13 IN CASE OF ANOMALY 13.1 PROBLEM SOLVING In case of doubts regarding the use of the stove, please contact ALWAYS the Authorized Technician on order to avoi irreparable damages! PROBLEM CAUSE SOLUTION Too large wood Use small and well dried wood logs during ignition, before bigger wood logs. Too humid wood Use well seasoned wood. Lack of chimney draught Open the registers completely. (If the problem persists, contact and expert stove repairer who will check the chimney flue efficiency).
PROBLEM CAUSE SOLUTION Lack of chimney draught Open the registers completely. (If the problem persists, contact and expert stove repairer who will check the chimney flue efficiency). Too humid wood Use well seasoned wood Too slow combustion Open air registers in order to increase the fire and fume output temperature. Bad quality fuel Use fuel described in FUEL page 11 INTERVENTION EN The glass blackens excessively 14 TECHNICAL DATAS 14.
14.
NOTE
pellet stoves· wood stoves· wood cooking stoves thermostoves· pellet fireplace inserts pelletkachels· houtkachels· houtkeukens thermokachel· open haard pellets CADEL srl FREEPOINT by Cadel Via Foresto Sud, 7 31025 Santa Lucia di Piave (TV) - ITALY tel. +39.0438.738669 fax +39.0438.73343 www.cadelsrl.com Partner of: Rev.