materials with thermal insulation and able to last against usual mechanical stresses.
It must be insulated to avoid condensation and to reduce fume cooling effects.
• The stove must be spaced out from fuels or ammable materials with an air gap or with insulating materials.
Check the distance with the chimney manufacturer.
• The chimney entrance must be placed in the same room where the appliance is installed or otherwise in
the adjacent room and it must be provided with a solid and condensation collection chamber under the
entrance, accessible through the sealed metal gate.
• Auxiliary exhaust fans cannot be installed neither along the chimney nor on the chimney pot.
• The inner section of the chimney ue can be round (the best one) or square and the jointed sides must have
a minimum radius of 20 mm.
• The section dimension must be:
• minimun Ø100 mm (for stoves up to 8.5 kw)
• minimun Ø120 mm (for stoves to 9 kw up)
• recommended max Ø180 mm
• Made the efciency of the chimney ue overhauled by an expert stove-repairer and if necessary cover the
chimney ue with materials in compliance with current regulations.
• The ue system must be placed on the roof.
• The chimney ue must be provided CE in accordance with EN 1443 regulation. Please nd attached an
example of label:
Fig. 3 - Example of label
9.4 HEIGHT-DEPRESSION
The depression (draught) of a chimney ue depends also on its height. Check the depression with the values
provided at FEATURES page 43. Minimum height 3,5 meters.
9.5 MAINTENANCE
• The fumes extraction pipes (fumes conduit + chimney ue + chimney pot) must always be cleaned, scrubbed
and checked by an expert stove-repairer, in compliance with current regulations, with the instructions of the
stove-manufacturer and the directives of your insurance company.
• In case of doubts, please follow the most restrictive regulations.
• Have your chimney ue and chimney pot checked and cleaned by an expert chimney sweep at least once
a week. The chimney sweep has to release a written declaration about the security of the system.
• Not cleaning compromise safety.
9.6 CHIMNEY POT
Fig. 4 - Anti-wind chimney pots
The chimney pot is important for the correct running of the heating appliance:
• We recommend using an anti-wind chimney pot, see Fig. 4 page 8.
• The hole width for fumes exhaust must be the double of the chimney ue width and tted in a way that the