Installation manual

GE Security
g
OPENING CODE COMMUNICATOR CODE
Segment 1 Opening Code for Codes 1-8 0
77 58
Segment 2-8 Reserved 0
CLOSING COMMUNICATOR CODE
Segment 1 Closing Code for Codes 1-8 0
78 58
Segment 2-8 Reserved 0
79 58 AUTOTEST COMMUNICATOR CODE 0-0
80 59 RECENT CLOSING AND EXIT ERROR 0-0
81 59 START PROGRAMMING / END PROGRAMMING 0-0-0-0
82 59 RESERVED / END DOWNLOAD 0-0-0-0
83 59 CANCEL COMMUNICATOR CODE 0
84-109
59 RESERVED
110 60 CONFIGURATION GROUP 1 ALARM CODE 4
CONFIGURATION GROUP 1 CHARACTERISTIC SELECT
Segment 1 (Circle Numbers To Program)
1 Fire (enable for fire zone) 5 Delay 1 zone (enable to follow Timer 1 Entry/Exit
times)
2 24 Hour (enable for non-fire 24 hour zone) 6 Delay 2 zone (enable to follow Timer 1 Entry / Exit
times)
3 Keyswitch zone 7 Interior (Enable for auto bypass or stay arming)
4 Follower (enable for burglary zones that are
instant during non-entry times)
8 Local Only (enable if zone is not to be reported)
Segment 2 (Circle Numbers To Program)
1 Keypad audible on alarm 5 Bypassable
2 Yelping siren on alarm 6 Group Shunt
3 Steady siren on alarm 7 Force armable
4 Chime 8 Entry Guard
Segment 3 (Circle Numbers To Program)
1 Fast Loop Response 5 Dialer Delay zone
2 Double End of Line Tamper zone 6 Swinger zone
3 Trouble zone (Fire and Day zone) 7 Restore reporting
4 Cross Zone 8 Listen-In
Segment 4 (Circle Numbers To Program)
1 Zone activity monitor 5 Reserved
2 End of line resistor defeat 6 Reserved
3 Zone acts as request to exit input 7 Reserved
4 Zone acts as acces control zone 8 Reserved
Segment 5 (Circle Numbers To Program)
111 60
1-8
Reserved
THE DEFAULTS LISTED IN THE ODD-NUMBERED LOCATIONS BELOW REPRESENT THE THREE
SEGMENTS OF EACH OF THOSE LOCATIONS. USE THE THREE SEGMENT CHARTS FROM
LOCATION 111 TO UNDERSTAND THESE DEFAULTS.
112 61 CONFIGURATION GROUP 2 ALARM EVENT CODE 2
113 61 CONFIGURATION GROUP 2 CHARACTERISTIC SELECT 2-125-278
114 61 CONFIGURATION GROUP 3 ALARM EVENT CODE 7
115 61 CONFIGURATION GROUP 3 CHARACTERISTIC SELECT 5-125-25678
116 61 CONFIGURATION GROUP 4 ALARM EVENT CODE 5
117 62 CONFIGURATION GROUP 4 CHARACTERISTIC SELECT 45-125-25678
118 62 CONFIGURATION GROUP 5 ALARM EVENT CODE 5
119 62 CONFIGURATION GROUP 5 CHARACTERISTIC SELECT 457-125-25678
120 62 CONFIGURATION GROUP 6 ALARM EVENT CODE 4
121 62 CONFIGURATION GROUP 6 CHARACTERISTIC SELECT 0-125-25678
NX-4-EUR Installation manual Page 78 08/09/04