Installation manual

GE Security
g
42 48 GO TO PROGRAM CODE 9-7-1-3-0-0
GO TO PROGRAM CODE PARTITION AND AUTHORIZATION
Segment 1 (Circle Numbers To Program)
1 Reserved
2 Enables “Go To Program Code” as an arm only code
3 Enables “Go To Program Code” as an arm only code after closing
4 Enables “Go To Program Code” as a master arm/disarm code (can change user codes)
5 Enables “Go To Program Code” as an arm/disarm code
6 Enables “Go To Program Code” to bypass zones
7 Enables “Go To Program Code” opening and closing reports
43
49
8 Reserved
44 49 DURESS CODE 15-15-15-15-15-15
45 50 RESERVED
AUXILIARY OUTPUTS 1-2 SPECIAL TIMING
Segments 1 2
Auxiliary output timed in minutes 1 1
Auxiliary output to latch 2 2
Auxiliary output to stop timing when user code is entered 3 3
Auxiliary output to activate only between closing and opening time 4 4
Auxiliary output to activate only between opening and closing time 5 5
Invert auxiliary output (0 volts going to 12 volts when activated) 6 6
Reserved 7 7
46 50
Reserved 8 8
AUXILIARY OUTPUT 1, EVENT & TIME (open collector 1)
Segment 1 Program the event number for output 1 7=Each siren activation
47 50
Segment 2 Program the timing for output 1 0 sec.=follow event
AUXILIARY OUTPUT 2, EVENT & TIME (relays 2 and open collector 2)
Segment 1 Program the event number for output 2 7=Each siren activation
48 50
Segment 2 Program the timing for output 1 0 sec.=follow event
49-50 50 RESERVED
AUTOTEST CONTROL
Segment 1 Program a “1” if the interval is hours, or a “0” for
days. Add a “2” to suppress the daily test or a “3” to
suppress the hourly test
0
Segment 2 Program the autotest interval from 1-255 days or
hours
1
Segment 3 Program the autotest report in 24 hour time format 2
51 52
Segment 4 Program the autotest report time, minutes after the
hour
0
OPENING TIME
Segment 1 Program the hour of the opening time 8
52 52
Segment 2 Program the minutes after the hour of the opening time 0
CLOSING TIME / AUTO ARMING TIME
Segment 1 Program the hour of the closing time / auto arming time 20
53 52
Segment 2 Program the minutes after hour of closing / auto arming time 0
NX-4-EUR Installation manual Page 76 08/09/04