Installation manual
GE Security
g
Reporting events to phone number 3
Phone N°3 can be used as a third receiver to multi-report or split report events. Phone
N°3 has two programming locations that are used to select the events that are reported to
this phone number. Location 16 is used to select which events are reported to phone N°3,
and location 17 is used to select which partitions are reported to phone N°3. If you do not
want dual or split reporting, location 16 and location 17 should be left at the factory
default of “0”. If you want multi-reporting or split reporting, and the split is based on the
event type (such as alarm, open/close, etc.), then location 16 should be used to select
only those events that should be reported to phone N°3, and location 17 should be left at
the factory default of “0”. If you want dual or split reporting, and the split is based on
partition, then location 16 should be programmed to “0” and location 17 should be used to
select those partitions that are to be reported to phone N°3. If no events are to be
reported to phone N°3, both locations should be at “0”.
LOCATION 16 - EVENTS REPORTED TO PHONE N° 3 (2 segments, feature selection data)
Segment 1
1 = Alarms
2 = Opening and closings
3 = Zone bypass and bypass restores
4 = Zone trouble and trouble restores
5 =
Power fail (AC failure), low battery, power restore (AC restore),
and low battery restore
6 = Bell cut, bell cut restore, telephone line restore
7 = Test reports
8 = Start and end programming, download complete and log full
Segment 2
1 = Zone and box tamper
2 = Auxiliary power overcurrent, and restore
3 = Wireless sensor missing and restore
4 = Wireless sensor low battery and restore
5 =
Expander trouble and restore (keypads are considered as
expanders)
6 = Fail to communicate
7 = Alarm restore
8 = Tamper restore
LOCATION 17 - Reserved
NX-4-EUR Installation manual Page 38 08/09/04