Swinger shutdown
This feature allows one or more zones to be bypassed automatically after a specified
number of alarms. If immediate restore is enabled in location 37, the alarms (and
restores, if this option is enabled) will be sent as they occur. If immediate restore is not
enabled, a second or subsequent alarm will not be sent until the siren times out (see
location 37 segment 2 and location 38).
Telephone line monitor
The NX-4 has a telephone line monitor which monitors the voltage and current of the
telephone line, in order to detect a faulty phone line. This condition can also be reported
to the central station. If the report is enabled, only the telephone line restore will be
reported. A telephone line cut is always logged (see locations 37 segment 3, location
39 and location 40 segment 5).
Two call answering machine defeat
If this option is enabled, two telephone calls must be made to the premises in order to
defeat an answering machine. On the first call, let the phone ring one or two times. The
control panel will detect these rings and start a 45-second timer; during this time, the
control panel will answer the next call on the first ring. This is not recommended for
commercial applications (see location 21).
User authorization to enter program mode
Entering program mode via the installer code is only possible within 60 seconds following
a user code entry (see location 41,segment1, option 6).
Walktest mode
Walktest mode is used to test your system without activating the siren and/or
communicator. The walktest mode is activated by pressing [*]-[chime] followed by the
master code.
Walktest mode is not possible if any partition is armed or if the communicator is active.
Wireless sensor absent/low battery
The NX-4 will send a report to the central station when a wireless sensor has detected a
low battery, or has not reported to the receiver. The “Service” LED will light up when
either of these conditions exists (see location 37 segment 4).
Zone activity monitor
This feature will send a report to the central station when a particular zone does not
change conditions within the specified number of hours/days programmed (see location
37, location 40 and locations 110-169).
Zone bypassed sounder alert
With this feature enabled, if a zone is bypassed, the NX-4 will beep the keypad sounder
when the zone is armed (see location 23 segment 2).
Zone Doubling
This feature allows you to use the four zones on the panel as eight normally closed
zones. When this feature is used, European double E.O.L. configuration cannot be used.
THIS FEATURE DOES NOT INCREASE THE TOTAL NUMBER OF AVAILABLE ZONES
BEYOND 8. If one of the eight zones must be a fire zone, it must be one of Zones 1 to 4.
The corresponding upper zone will become unavailable. For example: if Zone 4 is a fire
zone, then Zone 8 will not be available. (See location 37, segment 5).