Specifications

NX-216E Zone Expander
6
VI. DIP SWITCH SETTINGS (6 position)
The first thing that must be decided is the starting zone of this particular zone expander. The starting zone must be
on a boundary of eight (8) zones. The sixteen (16) zones for this module will move out from this starting position.
To set the starting zone, set the dip switch according to the table below:
THE POSITION OF ALL SWITCHES IS ONLY UPDATED WHEN THE NX-216E IS POWERED UP.
BEFORE YOU CHANGE THE POSITION OF THESE SWITCHES YOU MUST POWER DOWN THE EXPANDER.
Starting Zone #
Expander #
Switch 1 Switch 2 Switch 3
Switch 4 Switch 5
9
22
OFF OFF OFF
OFF OFF
9
23
ON OFF OFF
OFF OFF
17
16
OFF ON OFF
OFF OFF
25
17
ON ON OFF
OFF OFF
33
18
OFF OFF ON
OFF OFF
41
19
ON OFF ON
OFF OFF
49
20
OFF ON ON
OFF OFF
57
21
ON ON ON
OFF OFF
65
96
OFF OFF OFF
ON OFF
73
97
ON OFF OFF
ON OFF
81
98
OFF ON OFF
ON OFF
89
99
ON ON OFF
ON OFF
97
100
OFF OFF ON
ON OFF
105
101
ON OFF ON
ON OFF
113
102
OFF ON ON
ON OFF
121
103
ON ON ON
ON OFF
129
104
OFF OFF OFF
OFF ON
137
105
ON OFF OFF
OFF ON
145
106
OFF ON OFF
OFF ON
153
107
ON ON OFF
OFF ON
161
108
OFF OFF ON
OFF ON
169
109
ON OFF ON
OFF ON
177
110
OFF ON ON
OFF ON
185
111
ON ON ON
OFF ON
Dip switch 6 - Dip switch 6 is used to disable the second block of eight (8) zones on this zone expander. This can
be done if only an eight- (8) zone expander is required in a particular expander location. To disable the second
group of eight (8) zones on this expander, turn dip switch 6 on.