User Guide
12
OTHER KEYPAD FUNCTIONS
SETTING THE KEYPAD TONE
Step 1 Press [U]-[
0
]. Keypad is now in the “Adjust Tone” mode.
Step 2 Pressing the [
1
] key will make the keypad sounder go to higher
tones, pressing the [
2
] key will make the keypad sounder go to lower
tones.
Step 3 When the desired tone is reached, press the [
#
] key to set this tone
and exit from the “Adjust Tone” mode.
VIEW ALARM MEMORY
Step 1 Press [U]-[
3
]. The zone(s) that created the last alarm will be
displayed on the keypad.
Step 2 The
ALARM MEMORY
feature will flash those zones that created
alarms and will light steady those zones that were bypassed during
the last alarm.
TEST FUNCTION
– Optional
If programmed, this function will perform a battery test, communicator test, and/or
a siren test. No alarms will be sent and no reports will be sent unless a
communicator test is performed, at which time a test signal will be sent.
Step 1 Press [U]-[
4
]. The test will be performed as programmed.
Step 2 If the siren test is performed, enter a user code to silence the siren.
RESET FUNCTION
This function is used to reset Smoke Detectors, Zone Troubles, and Zone
Tampers.
Step 1 Disarm the system if not disarmed.
Step 2 Press [U]-[
7
]. Resets
have now been performed.
Step 3 If the keypad begins beeping, the reset did not execute properly.
Enter your code to silence the keypad. Wait a few minutes and
repeat step 2 to attempt another reset. If the keypad still beeps after
repeated attempts, please contact your installer.