SECURITY SYSTEM NOTES Installing / Service Company: For Service Call: Security System Configuration Master Code: " Quick Arm " Auxiliary Code(s) Digit: 2 3 4 5 6 7 Exit Delay Time Auxiliary Exit Delay Time Entry Delay Time Auxiliary Entry Delay Time Fire Alarm Sound Steady Siren 9 Pulsing Bell 9 Burglar Alarm Sound Yelp Siren 9 Steady Bell 9 Zone Coverage Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Zone 6: Emergency Phone Numbers Fire Dept.: Police Dept.
THIS MANUAL IS FURNISHED TO HELP YOU UNDERSTAND YOUR SECURITY SYSTEM AND BECOME PROFICIENT IN ITS OPERATION. ALL USERS OF YOUR SECURITY SYSTEM SHOULD READ AND FOLLOW THE INSTRUCTIONS AND PRECAUTIONS IN THIS BOOKLET. FAILURE TO DO SO COULD RESULT IN THE SECURITY SYSTEM NOT WORKING PROPERLY. THIS BOOKLET SHOULD BE KEPT IN AN ACCESSIBLE LOCATION FOR THE LIFE OF THE SECURITY SYSTEM.
HOW TO ARM YOUR SECURITY SYSTEM To Arm the security system, close all of the protected doors and windows. The green "READY" light on the keypad control will be illuminated when all of the protected zones and sensors are secure. If any of the zones are bypassed, a sensor in that zone can be violated without affecting the "READY" light. The security system will not arm if the "READY" light is not illuminated.
AUTOMATIC BYPASS OPTION If checked, the "AUTOMATIC BYPASS" option has been selected by your installing company. With this feature enabled, all interior zones will automatically bypass if you "ARM" your security system and do not leave through a designated entry/exit door. The "AUTOMATIC BYPASS" will occur at the end of the exit delay time. At this time, all bypassed "ZONE" lights will become illuminated.
KEYPAD ACTIVATED FIRE ALARM If checked, this feature has been selected by your installing company. If so, you can activate the Fire alarm by pressing the one [ 1] and three [3] keys at the same time for one second. If your system is connected to a monitoring center, an emergency report could be sent to that center. These keys should only be pressed in an emergency situation requiring response by fire department personnel. FIRE ZONE If checked, your system has zones designated as "FIRE" zones.
PROGRAMMING AUXILIARY CODES - In order to program Auxiliary Codes, you must know the Master Code. As stated earlier, each Auxiliary Code has its own unique number from 2, thru 7 and must be referred to by its number. It is programmed much like the Master Code.
KEYPAD CONTROL TONES (BEEPS) A sounder is built into the keypad and may sound for any of the following reasons: # Beeps for all keypresses. # Sounds a continuous tone during the Entry delay time. # Pulses when a "Day Zone" is violated, a zone configured for fire has a trouble condition, or when the armed status changes and the "Power" light if off.
EMERGENCY EVACUATION PLANS An emergency evacuation plan should be established for an actual fire alarm condition. For example, the following steps are recommended by the National Fire Protection Association and can be used as a guide in establishing an evacuation plan for your building. Draw up a floor plan of your home. Show windows, doors, stairs, and rooftops that can be used for escape. Indicate each occupant's escape routes. Always keep these routes free from obstruction.
SYSTEM NOTES 9