User Manual
57
The V6 offers two group sequence modes for
selection:
A-B-C-D: The f irst trigger in a series will
f ire group A, then group B, and so on. The
f ifth trigger will f ire group A and start
the cycle again. Another series will restart
at group A when there is no triggering event
in 2 seconds.
AB-CD: The f irst trigger in a series will
f ire group A and B together, then group C
and D. The third trigger will f ire group A
and B, and start the cycle again. Another
series will restart at group AB when there
is no triggering event in 2 seconds.