Owner's manual

503/503-P1 Series Industrial Grade SSD Product Manual v2.0Cactus Technologies
®
25
5.1.7. Idle, Idle Immediate-97H, E3H, 95H, E1H
These commands cause the drive to go into idle mode.
5.1.8. Initialize Drive Parameters-91H
The Initialize Drive Parameters command causes the drive to set BSY, enter the Idle (Read) mode,
clear BSY and generate an interrupt. This command enables the host to set the number of sectors
per track and the number of heads per cylinder. Only the Sector Count and the Drive/Drive/Head
registers are used by this command. This command is obsolete in ATA5 but is supported for
backwards compatibility.
Word
Address
Default
Value
Total
Bytes
Data Field Type Information
163 XXXXH 2 CFA advanced modes: supported and enabled bits
164 XXXXH 2
CFA advanced modes: 80ns I/O and Memory supported,
I/O and Memory UDMA modes supported and selected
165-168 0000H 8 Reserved
169 0001H 2 Trim bit in Data Set Management supported
170-216 0000H 94 Reserved
217 0001H 2 Solid State Device (non-rotating media)
218-254 0000H 74 Reserved
255 XXA5H 2 Integrity word
5.1.9. Media Lock/Unlock-DEH, DFH
These commands are NOP.
5.1.10. Read Buer-E4H
The Read Buer command enables the host to read the current contents of the SSD’s sector buer.
This command has the same protocol as the Read Sector(s) command.
5.1.11. Read DMA, Read DMA Ext-C8H, C9H, 25H
These commands read a number of sectors, as specied in the Sector Count register, in DMA mode
5.1.12. Read Log Ext-2FH
This command reads data from the general purpose log; the data read is described in the SMART log
section.
5.1.13. Read Multiple, Read Multiple Ext-C4H, 29H
The Read Multiple command performs similarly to the Read Sectors command. Interrupts are not
generated on every sector, but on the transfer of a block, which contains the number of sectors
dened by a Set Multiple, command.