Manual
Industrial Grade 203 Series IDE DOM Product Manual v2.0Cactus Technologies
®
12
The following table denes all D.C. Characteristics for the DOM Series. Unless otherwise stated,
conditions are:
Vcc = 5V ± 10% or Vcc = 3.3V ± 10%
Ta = -45°C to 90°C
Electrical Specication
3.3.
Parameter Symbol MIN MAX Units
Storage Temperature
Ts
-65 +150 °C
Operating Temperature
T
A
-45 +90 °C
Vcc with respect to GND
Vcc
-0.3 6.5 V
3.3.1. Absolute Maximum Ratings
Parameter Symbol MIN MAX Units
Input Voltage
V
in
-0.5 Vcc + 0.5 V
Output Voltage
Vout
-0.3 Vcc + 0.3 V
Input Leakage Current
I
LI
-10 10 uA
Output Leakage Current
I
LO
-10 10 uA
Input/Output Capacitance
C
I
/C
°
10 pF
Operating Current
Sleep Mode
@20 MHz (3.3V)
@40 MHz (3.3V)
@20 MHz (5.0V)
@40 MHz (5.0V)
I
cc
0.2
20
40
30
50
mA
3.3.2. DC Characteristics
3.3.3. AC Characteristics
3.3.3.1. Deskewing
The host shall provide cable deskewing for all signals originating from the device. The device
shall provide cable deskewing for all signals originating at the host.
All timing values and diagrams are shown and measured at the connector of the selected device.