Parameter Symbol Min Max
Data Delay after -IORD tdIORD 100
Data Hold following -IORD thIORD 0
-IORD Width Time twIORD 165
Address Setup before -IORD tsuA(IORD) 70
Address Hold following -IORD thA(IORD) 20
-CE Setup before -IORD tsuCE(IORD) 5
-CE Hold following -IORD thCE(IORD) 20
-REG Setup before -IORD tsuREG(IORD) 5
-REG Hold following -IORD th(REG(IORD) 0
-INPACK Delay Falling from -IORD tdfINPACK(IORD) 0 45
-INPACK Delay Rising from -IORD tdrINPACK(IORD) 45
-IOIS16 Delay Falling from Address tdfIOIS16(ADR) 35
-IOIS16 Delay Rising from Address tdrIOIS16(ADR) 35
1. All timings in ns.
2. The maximum load on -INPACK and -IOIS16 is 1 LSTTL with 50 pF total load.
Table 3-8. I/O Read (Input) Timing Specication