Cactus Technologies Industrial DOM is a dual voltage product, which means it will operate at a
voltage range of 3.30 volts ±10% or 5.00 volts ± 10%.Product Specications
For all the following specications, values are dened at ambient temperature and nominal supply
voltage unless otherwise stated.
System Environmental Specications
2.1.
Table 2-1. Environmental Specications Cactus Industrial UFD
Temperature
Operating:
0° C to +70° C (Standard)
-45° C to +90° C (Extended)
Humidity
Operating & Non-Operating:
8% to 95%, non-condensing
Acoustic Noise
0 dB
Vibration
Operating & Non-Operating:
20 G MIL-STD-883G Method 2007.3
condition A
Shock
Operating & Non-Operating:
3,000 G MIL-STD-883G Method 2002.4
condition C
Altitude
(relative to sea level)
Operating & Non-Operating:
100,000 feet maximum
System Power Requirements
2.2.
Table 2-2. Power Requirements Cactus Industrial UFD
DC Input Voltage (VCC)
100 mV max. ripple (p-p)
5.0V ±10%
(Maximum Average Value)
See Notes.
Standby:
Reading:
Writing:
58 mA
130 mA
130 mA
NOTES: All values quoted are typical at ambient temperature and nominal supply voltage unless otherwise stated.
Sleep mode is specied under the condition that all drive inputs are static CMOS levels and in a “Not Busy“ operating state.
Power
Supply Requirements02