Manual

100 Series Industrial Grade UFD Product Manual v2.0Cactus Technologies
®
4
Cactus Technologies Industrial DOM is a dual voltage product, which means it will operate at a
voltage range of 3.30 volts ±10% or 5.00 volts ± 10%.Product Specications
For all the following specications, values are dened at ambient temperature and nominal supply
voltage unless otherwise stated.
System Environmental Specications
2.1.
Table 2-1. Environmental Specications Cactus Industrial UFD
Temperature
Operating:
0° C to +70° C (Standard)
-45° C to +90° C (Extended)
Humidity
Operating & Non-Operating:
8% to 95%, non-condensing
Acoustic Noise
0 dB
Vibration
Operating & Non-Operating:
20 G MIL-STD-883G Method 2007.3
condition A
Shock
Operating & Non-Operating:
3,000 G MIL-STD-883G Method 2002.4
condition C
Altitude
(relative to sea level)
Operating & Non-Operating:
100,000 feet maximum
System Power Requirements
2.2.
Table 2-2. Power Requirements Cactus Industrial UFD
DC Input Voltage (VCC)
100 mV max. ripple (p-p)
5.0V ±10%
(Maximum Average Value)
See Notes.
Standby:
Reading:
Writing:
58 mA
130 mA
130 mA
NOTES: All values quoted are typical at ambient temperature and nominal supply voltage unless otherwise stated.
Sleep mode is specied under the condition that all drive inputs are static CMOS levels and in a “Not Busy“ operating state.
Power