 Troubleshooting Chart 4
IGNITER/SENSOR WARMS
UP AND GLOWS 
YELLOW/ORANGE
DURING 20 SECOND 
WARM UP
CHART 3
YES
NO
CHECK FOR 120 VAC 
BETWEEN TERMINALS 1 
AND 2 AT CONNECTOR 
CN1 ON IBC (DURING 
IGNITER WARM UP) 
NO
REPLACE IBC
YES
CHECK FOR 120 VAC AT 
IGNITER/SENSOR LEADS 
ON WIRING HARNESS 
(DURING IGNITER 
WARM UP)
NO
REPAIR/REPLACE WIRING 
FROM IBC 
TO IGNITER/SENSOR
YES
REPLACE IGNITER/SENSOR
AFTER 20 SECOND 
IGNITER WARM UP, GAS 
VALVE IS ENERGIZED 
VALVE LIGHT IS ON
2 SECONDS LATER POWER 
IS REMOVED FROM 
IGNITER/SENSOR
IGNITER LIGHT IS OFF
DOES MAIN BURNER 
LIGHT?
CHECK FOR 24 VAC 
ACROSS TERMINALS MV 
ON THE GAS CONTROL. 
WHILE VALVE/FLAME 
INDICATOR LIGHT IS ON
NO
NO
CHECK FOR 24 VAC 
ACROSS TERMINALS 
CN6-2 AND CN6-5 ON 
IBC, WHILE THE VALVE/
FLAME LED IS LIT
NO
REPLACE IBC
YES
REPAIR/REPLACE WIRING 
BETWEEN IBC AND 
GAS CONTROL
YES
CHECK IF IGNITER/
SENSOR POSITION IS OK?
TIP SHOULD BE SLANTED 
TOWARDS BURNER
RESTORE IGNITER/SENSOR 
TO CORRECT POSITION.
DO NOT RELOCATE
NO
YES
CHECK GAS SUPPLY 
PRESSURE AT INLET 
PRESSURE TAPPING ON 
GAS CONTROL IS GAS 
PRESSURE GREATER 
THAN 4.0" W.C.?
NO
ARE ALL MANUAL 
SHUT-OFFS IN THE GAS 
SUPPLY LINE AND ON 
THE GAS CONTROL IN 
THE OPEN OR ON 
POSITION?
OPEN OR TURN ON ALL 
MANUAL SHUTOFFS
NO
YES
CONTACT THE GAS UTILITY 
TO TURN THE GAS ON
YES
CHART 5
CHART 5
YES
YES
15 - TROUBLESHOOTING