Specifications

9030992 E6 ConfigurationViews
3-19
Station Detail View
This button opens the Station Alarms Configuration view, which allows you to
change the threshold value and state on the station for the Line, Burst, A/C,
Internal, and Receive Congestion errors.
Configure Station Alarms
Table 3-1. Frame Breakdown Pie Chart
Statistic Definition
Frames The total number of frames detected on this station or ring.
Errors The total number of errors detected by this station or ring.
Table 3-2. Isolating Errors Pie Chart
Statistic Definition
Line The total number of line errors that have occurred on this ring.
Burst The total number of burst errors that have occurred on this ring.
The total number of address/copied errors that have occurred on
this ring.
Abort Sequence The total number of abort sequences transmitted on this ring.
Internal The total number of internal errors detected by station on this
ring.
Table 3-3. Non-Isolating Errors Pie Chart
Statistic Definition
Lost Frames The total number of times a station has had its TRR timer expire
while trying to transmit.
Congestions The total number of times a station recognizes a frame addressed
to it, but has no available buffer space.
Frame Copied The total number of times a station recognizes a frame addressed
to it, and detects that the FS field A bits are set to 1.
Token The total number of times the station acting as active monitor
recognizes an error condition requiring a token be transmitted.
Frequency The total number of frequency errors on this ring.