Specifications
Station Alarm Thresholds View
ConfigurationViews TRXI
3-16 Management Module Guide
This button opens the Station Detail view, which is described later in this
chapter.
This button opens the Station Alarms dialog box, which is described later in
this chapter.
This button allows you to remove the selected station from the ring.
Station Alarm Thresholds View
This view displays a Station Alarm Thresholds Table containing information
for all stations directly connected to the TRXI device, buttons to manipulate
the information in the table, and buttons to access other views. You can access
this view through the Alarms Table button in the Token Ring Station Table
view. The information displayed by this view is as follows:
Ring Name
The ASCII name assigned to this ring. This name defaults to Network n,
where n is a unique integer value.
Ring Number
The number of the attached ring. If SPECTRUM cannot determine the
number of the ring, a zero is returned.
Ring Speed
The speed of the ring, which can have a value of 4 or 16 megabits.
Ring Status
The operational state of the ring.
Active Monitor
The MAC address of the active monitor for the ring. This address will appear
in any table with an asterisk (*) to identify it.
Station Address
The MAC address of the station to which this information pertains.
Station Name
The ASCII name assigned to this station.
Line
The current alarm threshold setting for line errors on the device.
Burst
The current alarm threshold setting for burst errors on the device.
Station Detail
Station Alarms
Remove Station