Specifications

Token Ring Isolating Errors Table
ConfigurationViews TRXI
3-12 Management Module Guide
This button opens the Station Alarms dialog box, which is described later in
this chapter.
This button allows you to remove the selected station from the ring.
This button opens the 802.5 Station Isolating Errors view, providing the same
information and button functions as the Station Isolating Errors View
described later in this chapter.
This button opens the 802.5 Configuration view, which provides the same
information and button functions as the TRXI Device Configuration view
described earlier in this chapter.
Token Ring Isolating Errors Table
This view displays an Isolating Errors Table containing information for all
stations directly connected to the TRXI device, buttons to manipulate the
information in the table, and buttons to access other views. You can access this
view through the Isolating Errors Table button in the Token Ring Station
Table view. The information displayed by this view is as follows:
Ring Name
The ASCII name assigned to this ring. This name defaults to Network n,
where n is a unique integer value.
Ring Number
The number of the attached ring. If SPECTRUM cannot determine the
number of the ring, a zero is returned.
Ring Speed
The speed of the ring, which can have a value of 4 or 16 megabits.
Ring Status
The operational state of the ring.
Active Monitor
The MAC address of the active monitor for the ring. This address will appear
in any table with an asterisk (*) to identify it.
Station Address
The MAC address of the station to which this information pertains.
Station Alarms
Remove
Isolating Errors
Configuration