Specifications
Ring Configuration View
ConfigurationViews TRXI
3-4 Management Module Guide
Ring Configuration View
This view allows you to modify the values of some fields. You can access this
view through the Ring Configuration button in the Configuration View.
Ring Configuration
This section of the Ring Configuration view displays the following
information:
Ring Name
The ASCII name assigned to this ring. This name defaults to Network n,
where n is a unique integer value.
Ring Number
The number of the attached ring. If SPECTRUM cannot determine the
number of the ring, a zero is returned.
Ring Speed
The speed of the ring, which can have a value of 4 or 16 megabits.
Ring Status
The operational state of the ring.
Active Monitor
The MAC address of the active monitor for the ring. This address will appear
in any tables with an asterisk (*) to identify it.
Active Stations
The number of active stations currently inserted on the ring.
This button allows you to Enable or Disable automatic beacon recovery for
the TRXI. When Disabled, the TRXI will not attempt to reinsert itself into the
ring after entering a beaconing state. If the device does not support automatic
beacon recovery, SPECTRUM will display a status of Invalid.
Ring Alarm/Threshold/State
This section of the Ring Configuration view has three columns, displaying
information on the ring alarms, their current thresholds, and their states
(Enabled or Disabled). The applicable ring alarms are as follows:
Ring Purges
The threshold field allows you to set a value for the Ring Purges alarm
threshold, and the state button allows you to Enable or Disable detection of
this alarm.
Beacon Recovery