Technical data
TRBMIM Events and Alarms
Event and Alarm Messages TRBMIM
4-10 Management Module Guide
CsEvFormat/Event0042020d
{d Ò%w- %d %m-, %Y - %TÓ} - BOARD BYPASSED
DURING FAULT RECOVERY - Device {m} of
Type {t} reported that Module {I 1} was Bypassed
during a Fault Recovery Condition. - (event [{e}])
CsPCause/Prob0042020d
BOARD BYPASSED DURING FAULT
RECOVERY
SYMPTOMS:
A Module was Bypassed during a Fault Recovery
Condition.
PROBABLE CAUSES:
1) This Module is conÞgured with a different Ring
Speed than the Hub.
RECOMMENDED ACTIONS:
1) Pull out the Bypassed Module from the Hub.
2) Re-conÞgure this ModuleÕs Ring Speed to match
that of the Hub.
3) Physically insert the Module back into the Hub.
4) Set this ModuleÕs Bypass State to Inserted.
CsEvFormat/Event0042020e
{d Ò%w- %d %m-, %Y - %TÓ} - PORT VIOLATION
- Device {m} of Type {t} reported that Port {I 2} in
Module {I 1} has detected a Link while the PortÕs
Management State was Disabled. - (event [{e}])
CsPCause/Prob0042020e
PORT VIOLATION
SYMPTOMS:
A Link has been detected for a Port while its
Management State was Disabled.
PROBABLE CAUSES:
1) A Physical connection has been made between a
Station and a Port while the PortÕs Management
State was Disabled.
RECOMMENDED ACTIONS:
1) If the Station belongs on this Ring, then Enable
the PortÕs Management State.
2) If the Station does not belong on this Ring, then
physically disconnect the Intruding Station from
the Port.
Table 4-1. TRBMIM Events and Alarms (Sheet 9 of 23)
System Event Log Message
Source and Text
Alarm View Probable Cause Message
Source and Text