Technical data
9031251 E6 Event and Alarm Messages
4-5
TRBMIM Events and Alarms
CsEvFormat/Event0042011e
{d Ò%w- %d %m-, %Y - %TÓ} - FAN ABNORMAL -
Device {m} of Type {t} reported that a Fan in the
Chassis has Failed or is operating at an abnormal
RPM rate. - (event [{e}])
CsPCause/Prob0042011e
FAN ABNORMAL
SYMPTOMS:
A problem has been detected with a Cooling Fan
or the Fan Tray Assembly for this device.
RECOMMENDED ACTION:
This failure should be addressed before
overheating causes damage to the device. Check
for fan failures in the Chassis and repair as
needed.
CsEvFormat/Event0042011f
{d Ò%w- %d %m-, %Y - %TÓ} - FAN NORMAL -
Device {m} of Type {t} reported that a Fan in the
Chassis has resumed Normal Operation. - (event
[{e}])
No probable cause message.
CsEvFormat/Event00420125
{d Ò%w- %d %m-, %Y - %TÓ} - VOLTAGE LOW -
Device {m} of Type {t} reported that the System
Power Supply Voltage is Low. - (event [{e}])
CsPCause/Prob00420125
VOLTAGE LOW
SYMPTOMS:
The internal voltage of the System Power Supply
is Low.
PROBABLE CAUSES:
1) The Power Supply unit is defective.
2) An AC Power Failure has occurred in the
System Power Supply.
RECOMMENDED ACTIONS:
1) Check the System Power Supply unit on the
device.
2) Check Power source to device.
CsEvFormat/Event00420126
{d Ò%w- %d %m-, %Y - %TÓ} - VOLTAGE
NORMAL - Device {m} of Type {t} reported that
the System Power Supply Voltage has returned to
Normal. - (event [{e}])
No probable cause message.
Table 4-1. TRBMIM Events and Alarms (Sheet 4 of 23)
System Event Log Message
Source and Text
Alarm View Probable Cause Message
Source and Text